Usage: | Electric Safety Test |
---|---|
Power: | Electronic |
Model Number: | CX-L19 |
Brand Name: | Chuangxin |
Place of Origin: | China (Mainland) |
Standard: | IEC60112 |
Quick Details
Specifications
Electrode Material |
Electrode tip: Platinum |
Electrode Force |
1.0±0.05N |
Electrode Distance |
4.0mm±0.01mm, included angle: 60°±5° |
Electrode Voltage |
100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10% |
Drip Height |
30~40mm, adjustable |
Drip Size |
44~45 drip/CBM, adjustable |
Drip Timing |
30s±5s, adjustable |
Drip Times |
0~9999 times, adjustable |
Leakage judgment |
When the loop current above 0.5A and keeps 2s, and the machine break the current, indicate the specimen is disqualification |
Test Process |
Auto-control, and independent convulsions |
Standard |
IEC60112, GB/T4207, GB4706.1 |
Studio Volume |
0.5CBM |
Dimension |
W630mm*D390mm*H750mm |