Product Main

Specifications

PV Cable Temperature range for application -40℃up to 90℃
Short circuit resistance up to +200℃ 5S
High resistance against UV , ozone and hydrolysis
Very high mechanical robustness and resistance against water . Oil and chemicals
Compact and flexible
Years of approved application worldwide
It is approvalled by TUV and UL

Cross Section

Rated Voltage

Conductor

Cable Diameter

Conductor Resistance

2.5mm2

IEC1000V

49*0.25mm

5.5± 0.1mm

≤ 8.21Ω /㎞

4.0mm2

IEC1000V

56*0.3mm

6.4± 0.3mm

≤ 5.09Ω /㎞

6.0mm2

IEC1000V

84*0.3mm

7.2± 0.3mm

≤ 3.39Ω /㎞

14AWG

UL600V

41*0.254mm

5.9± 0.2mm

≤ 8.96Ω /㎞

12AWG

UL600V

65*0.254mm

6.3± 0.2mm

≤ 5.64Ω /㎞

10AWG

UL600V

65*0.32mm

7.0± 0.2mm

≤ 3.564Ω /㎞

2.5mm2/14AWG

IEC1000V/UL600V

49*0.25mm

6.1~6.5± 0.15mm

≤ 8.21Ω /㎞

4.0mm2/12AWG

IEC1000V/UL600V

56*0.3mm

6.6~6.9± 0.1mm

≤ 5.09Ω /㎞

6.0mm2/10AWG

IEC1000V/UL600V

84*0.3mm

7.5± 0.2mm

≤ 3.39Ω /㎞

2.5mm2/14AWG

IEC1000V/UL600V

49*0.25mm

6.7± 0.15mm

≤ 8.21Ω /㎞

4.0mm2/12AWG

IEC1000V/UL600V

56*0.3mm

7.4± 0.2mm

≤ 5.09Ω /㎞

6.0mm2/10AWG

IEC1000V/UL600V

84*0.3mm

8.0± 0.1mm

≤ 3.39Ω /㎞