Specifications

40 CH 100G AWG Module 40 CHannel DWDM Mux/Demux

Flyin Optronics offers a full range of AWG products, including 50GHz, 100GHz and 200GHz AWG. Here we present the generic specification for the 40-channel 100GHz AWG MUX/DEMUX component supplied for use in DWDM system.
 
This component is designed for use within the C -band release of DWDM system. To decrease the power dissipation of the devices in different environmental conditions, the AWG package is special designed with selection of reliable thermal plastic with low thermal conduction, and the AWG operating temperature is controlled by using foil resist heater or Peltier TEC with thermistor temperature sensor. Different input and output fibers, such as SM fibers, MM fibers and PM fiber can be selected to meet different applications. We can also offer different package for different products, inluding ABS box and 19"  1U rackmount.

Optical Specification  (Flattop AWG)
Parameters
Condition
Specs
Units
Min
Typ
Max
Number of Channels
 
40
 
Number Channel Spacing
100GHz
100
GHz
Cha. Center Wavelength
ITU frequency.
C -band
nm
Clear Channel Passband
 
±0.1
nm
Wavelength Stability
Maximum range of the wavelength error  of all channels and temperatures in average polarization.
±0.05
nm
-1 dB Channel Bandwidth
Clear channel bandwidth defined by passband shape. For each channel
0.4
 
 
nm
-3 dB Channel Bandwidth
Clear channel bandwidth defined by passband shape. For each channel
0.6
 
 
nm
Optical Insertion Loss at ITU grid
Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations.
 
4.5
6.0
dB
Adjacent Channel Isolation
Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the adjacent channels.
25
 
 
dB
Non-Adjacent, Channel
Isolation
Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the nonadjacent channels.
30
 
 
dB
Total Channel Isolation
Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels.
22
 
 
dB
Insertion Loss Uniformity
Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures.
 
1.0
1.5
dB
Directivity(Mux Only)
Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n
40
 
 
dB
Insertion Loss Ripple
Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port
 
 
0.5
dB
Optical Return loss
Input & output ports
40
 
 
dB
PDL/Polarization Dependent Loss in Clear
Channel Band
Worst-case value measured in ITU band
 
0.3
0.5
dB
Polarization Mode
Dispersion
 
 
 
0.5
ps
Maximum Optical Power
 
 
 
23
dBm
MUX/DEMUX input/ output
Monitoring range
 
-35
 
+23
dBm
IL Represents the worst case over a +/-0.1nm window around the ITU wavelength
PDL was measured on average polarization over a +/- 0.1nm window around the ITU wavelength.
 
Ordering Part Code Sequence
AWG
X
XX
X
XXX
X
X
X
XX
 
Band
Number of Channels
Spacing
1st Channel
Filter Shape
Package
Fiber Length
In/Out Connector
C=C-Band
L=L-Band
D=C+L-Band
X=Customize
16=16-CH
32=32-CH
40=40-CH
48=48-CH
XX=Special
1=100G
2=200G
5=50G
X=Special
C60=C60
H59=H59
C59=C59
H58=H58
XXX=special
G=Gaussian
B=Broad Gaussiar
F=Flat Top
M=Module
R=Rack
X=Special
1=0.5m
2=1m
3=1.5m
4=2m
5=2.5m
6=3m
S=Specify
0=None
1=FC/APC
2=FC/PC
3=SC/APC
4=SC/PC
5=LC/APC
6=LC/PC
7=ST/UPC
S=Specify