Product Main

Specifications

Heated Desiccant Air Dryer
Introductions of Air Dryer

Tower, one set of switching valves and one set of controlling system. In the switching time, one tower is adsorbing while the other one is regenerating. When adsorbing, the compressed air flow through the air inlet valve, then flow into the tower to adsorb. When regenerating, a portion of dried air is diverted from the main pipeline as regeneration gas, then through the throttle orifice to reduce it’ s pressure. Regeneration gas flow by inlet valve into the adsorber to regenerating , then pass through the outlet valve and be discharged through the muffle to atmosphere.

Features

u Adopt technology of pressure swing adsorption , regeneration without heat;

u Short switch cycle;

u Adopt PIC automatic controller;

u Simple process, low failure rate, low investment cost;

u Integrated delivery, Easy tomaintainand operate;

u Famous brand components to ensure long time running;

u Need to consume a certain portion of purge air .

 

Main Technical Data

Working pressure: 5~10 bar

Inlet temperature: ≤ 45° C

Ambient temperature: ≤ 45° C

Pressure Dew point: ≤ -40° C

Purge loss: 14.5%

Switch time: 5~10min

Pressure drop: ≤ 0.21bar

Desiccant: activated alumina

Inlet oil content: ≤ 0.1ppm(w)

Control method: PIC controller

Power supply: 220V/1PH/50HZ