Classification: Laboratory Heating Equipments
Brand Name: SGM
Classification: Laboratory Heating Equipments
name: Ultra-High Temperature Box Resistance Furnace
Working temperature: 1700C
heating rate: 0~10C/MIN
Place of Origin: China (Mainland)
Model Number: SGM.M6/17

Specifications


1600 Degree Box Resistance Furnacehigh temperature furnacelab furnacemuffle furnace

1600 Degree Box Resistance Furnace
High-temperature box resistance furnace 1600℃-1700℃ (Muffle furnace)

SGM series of high-temperature laboratory furnaces have the perfect design, possess many patents, the safety, reliability and practicability of which all show the best performance.

1. the highest temperature reaches 1600℃-1700℃.

2. Adopt the patent structure of double furnace chambers and special furnace-top building technology which have the advantages of fast heating, not collapsing in over-high temperature or dropping ashes in high temperature. Use the vacuum forming technology to produce the inorganic fiber as heat preservation materials and special insulation design.

3. MoSi2 rods are set in both sides of the chamber which is easy to change.

4. the furnace body is made of superior double-layer carbon steel which has the advantages of heat insulation and low temperature.

5. Designed with the following functions:

SCR control; transformer regulating; PID parameter self-setting; manual or automatic switch without interference; over-temperature alarm; temperature compensation and correction; the built-in parameter password to control the furnace;

6. the heating rate is 5-15℃/min. There are 50 programmable periods to control the temperature to rise automatically. 

7. High precision of temperature control is within ±1℃ and over-temperature value is less than 3℃.

8. the multiple safety protection design provides good safety and long working life.

9. Users could select paperless recorder or RS232 communication interface to realize the field control through the computer and record the historical data and heat-rising curves without paper.

10. Field debugging, training and fire-prevention door are offered for free.

Extra equipments:

1.      Exhaust chimney

2.      Spare parts

3.      Users can choose the function of automatically power off once the door is opened.

 
 
Model
Volume
Max.Temperature
Chamber size(mm) (WXLXH)
Outer size(mm) (WXLXH)
Power(KW)
Voltage (V)
SGM·M6/16
6L
1600℃
150×300×120
520×635×1600
8
380
SGM·M11/16
11L
1600℃
200×300×180
520×635×1600
12
380
SGM·M15/16
15L
1600℃
200×400×180
520×735×1600
16
380
SGM·M25/16
25L
1600℃
250×400×250
570×735×1700
20
380
SGM·M38/16
38L
1600℃
300×500×250
620×835×1800
24
380
SGM·M6/17
6L
1700℃
150×300×120
520×635×1600
6
380
SGM·M11/17
11L
1700℃
200×300×180
520×635×1600
8
380
SGM·M15/17
15L
1700℃
200×400×180
520×735×1600
12
380
SGM·M25/17
25L
1700℃
250×400×250
570×735×1700
14
380
SGM·M38/17
38L
1700℃
300×500×250
620×835×1800
20
380