| Dimensions: | 78*90 |
|---|---|
| Accuracy Class: | 0.2 |
| Phase: | Three Phase |
| Display Type: | Digital Only |
| Brand Name: | Blue Jay |
| Operating Temperature: | -40-85 |
| Output Voltage: | 85-265 |
| Measuring Energy Range: | 0-999999 |
| Model Number: | DEM-4MC |
Quick Details
Specifications
the DEM-4MC three-phase rail-mounted energy meter is an ideal choice for residential billing, room rental billing, and industrial applications. with a width of 4 modules and a default 100mA/333mV CT, it can use external current transformers to extend the current measurement range up to 999A. In addition to basic voltage, current, frequency and other basic energy measurement functions, the DEM-4MC can optionally measure advanced parameters such as demand record and voltage and current imbalance detection.
the DEM-4MC features CATIII-300V voltage rating and and withstand voltage of 2kV, ensuring safety and reliability in complex electrical environments. the DEM-4MC provides real-time voltage and current readings through an LCD screen and supports RS485-RTU and pulse output ports. It can be expanded with multiple DI/DO ports, offering users a comprehensive energy management solution. Compliant with international standards IEC61557 and IEC62053, the DEM-4MC is suitable for the diverse needs of residential, public facility, and industrial scenarios.

Specification
the DEM-4MC features CATIII-300V voltage rating and and withstand voltage of 2kV, ensuring safety and reliability in complex electrical environments. the DEM-4MC provides real-time voltage and current readings through an LCD screen and supports RS485-RTU and pulse output ports. It can be expanded with multiple DI/DO ports, offering users a comprehensive energy management solution. Compliant with international standards IEC61557 and IEC62053, the DEM-4MC is suitable for the diverse needs of residential, public facility, and industrial scenarios.
Specification
| PArameter | Value |
| Auxiliary power | 85-265Vac/DC |
| Voltage measurement | Rated 110V, 380V RMS value, Accuracy 0.2s, |
| Current measurement | Rated 5A, optional 1A, CT connection |
| Frequency | 50/60Hz, Accuracy ±0.01Hz |
| Display | LCD with white backlit |
| Maximum display value | 9,999MWh |
| Curr& volt accuracy | 0.5%, (IEC 61557-12) |
| Active energy accuracy | Class 1.0, (IEC 62053-22) |
| Reactive energy accuracy | Class 2.0, (IEC 62053-23) |
| Pulse constant | 1 channel, 5000imp/kWh |
| I/O module | 2DO, 2DI optional |
| Communication | RS-485 MODBUS-RTU |
| Withstand voltage | 2.5KV 1min |
| Insulation | Input, output, power supply to shell >5MΩ |
| Storage environment | -40~70°C |
| Working environment | -25~55°C Altitude ≤2500m, 0~95%RH, non-condensing, non-corrosive gas |