Product Main

Specifications

AAAC cable is widely used for overhead power transimission,we can produce as per IEC,BS,ASTM,CSA,DIN,JIS Standard 

AAAC cable (All Aluminium Alloy Conductor) is widely used in power transmission lines with various voltage levels.

AAAC (all aluminum alloy Conductor) referred to have higher strength but lower conductivity than pure aluminum.being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;having lower breaking loads than the latter,their use becomes particularly favourable when ice and win loadings are low.
 We can supply this conductor according to different recognized standards,such as BS EN50182,IEC61089,ASTM B399DIN 48, customer special specification also can be satisfied.
 
The data sheets below show the most common standards,British standard and IEC standard.
 
 
IEC Sizes IEC 61089
 
 
Code Number
Stranding&wire diameter
Approx Overall diameter
Nominal
area
Approx.
Weight
Breaking Load
DC Resistance at 20
mm
mm
mm2
Kg/km
KN
Ohm/km
16
25
40
63
100
125
160
200
250
315
400
450
500
560
630
710
800
900
1000
1120
1250
7/1.83
7/2.29
7/2.89
7/3.63
19/2.78
19/3.10
19/3.51
19/3.93
19/4.39
37/3.53
37/3.98
37/4.22
37/4.45
61/3.67
61/3.89
61/4.13
61/4.38
91/3.81
91/4.01
91/4.25
91/4.49
 
5.49
6.86
8.68
10.9
13.9
15.5
17.6
19.6
22.0
24.7
27.9
29.6
31.2
33.0
35.0
37.2
39.5
41.8
44.1
46.7
49.4
18.4
28.8
46.0
72.5
115
144
184
230
288
363
460
518
575
645
725
817
921
1036
1151
1289
1439
50.4
78.7
125.9
198.3
316.3
395.4
506.1
632.7
790.8
998.9
1268.4
1426.9
1585.5
1778.4
2000.7
2254.8
2540.6
2861.1
3179.0
3560.5
3973.7
5.43
8.49
13.58
21.39
33.95
42.44
54.32
67.91
84.88
106.95
135.81
152.79
169.76
190.14
213.90
241.07
271.62
305.58
339.53
380.27
424.41
1.7896
1.1453
0.7158
0.4545
0.2877
0.2302
0.1798
0.1439
0.1151
0.0916
0.0721
0.0641
0.0577
0.0516
0.0458
0.0407
0.0361
0.0321
0.0289
0.0258
0.0231
 
 
 
 
 
BS EN 50182:2001
 
Code Name
Stranding&wire diameter
Approx Overall diameter
Total area
Weight
Breaking Load
DC Resistance at 20
Current Rating
mm
mm
mm2
Kg/km
KN
Ohm/km
A
Box
Acacia
Almond
Cedar
 
Deodar
Fir
Hazel
Pine
Holly
Willow
Oak
 
Mulbery
Ash
Elm
Poplar
Sycamore
Upas
Yew
 
Totara
Rubus
Sorbus
Araucaria
Redwood
7/1.85
7/2.08
7/2.34
7/2.54
 
7/2.77
7/2.95
7/3.30
7/3.61
7/3.91
7/4.04
7/4.65
 
19/3.18
19/3.48
19/3.76
37/2.87
37/3.23
37/3.53
37/4.06
 
37/4.14
61/3.50
61/3.71
61/4.14
61/4.56
5.55
6.24
7.02
7.62
 
8.31
8.85
9.90
10.80
11.70
12.10
13.95
 
15.90
17.40
18.80
20.10
22.60
24.70
28.40
 
29.42
31.50
33.40
37.30
41.00
18.8
23.9
30.1
35.5
 
42.2
47.8
59.9
71.6
84.1
89.7
118.9
 
150.9
180.7
211.0
239.4
303.2
362.1
479.0
 
498.1
586.9
659.4
821.1
996.2
51.4
64.9
82.2
96.8
 
115.2
130.6
163.4
195.6
229.5
245.0
324.5
 
414.3
496.1
579.2
659.4
835.2
997.5
1319.6
 
1372.1
1622.0
1822.5
2269.5
2753.2
5.55
7.02
8.88
10.46
 
12.44
14.11
17.66
21.14
24.79
26.47
35.07
 
44.52
53.31
62.24
70.61
89.40
106.82
141.31
 
146.93
173.13
194.53
242.24
293.88
1.7480
1.3828
1.0926
0.9273
 
0.7797
0.6875
0.5494
0.4591
0.3913
0.3665
0.2767
 
0.2192
0.1830
0.1568
0.1387
0.1095
0.0917
0.0693
 
0.0666
0.0567
0.0505
0.0406
0.0334
93
110
128
132
 
148
161
184
204
222
233
272
 
319
354
385
414
487
527
629
 
640
716
760
842
920