Product Main

Specifications

LOW VOLTAGE  POWER CABLE

 including CU OR AL/PVC/PVC OR PE, CU OR AL/PVC/SWA/PVC OR PE,CU OR AL/XLPE/PVC OR PE,CU OR AL/XLPE/SWA/PVC OR PE, ONE CORE AND MULTI-CORE, IEC60502

 
Conductor:
Solid or stranded Copper/Aluminum
-Insulation:
Cross-linked polyethylene( XLPE or PVC)
-Circuit Identication:
The insulation shall be red, black
-Filler:
Polypropylene lament with lapped binding tape
-Inner Sheath:
Polyvinyl chloride (Black)
-Armor:
Galvanized steel wire/steel tape/Unarmored/Aluminum wire
-Core-covering:
Binding tape
-Outer Sheath:
Polyvinyl chloride (Black) OR PE
-Application:
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
-Standards / Testing Specications:
IEC 60502-1

Installation
This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed,so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
 
 
The Application of Power Cable
Power Cable is used to transmit power on power distribution circuit of AC 50HZ, rated voltage 35 KV or lower. It has not only excellent electrical performance, mechanical performance, heat-resistant & anti-aging performance, environment resistant character & chemical-corrosion resistant performance, but simple structure, light weight, without restriction by laying fall, and it also has high temperature (90) for long term

Instruction
I. Executive Standard: GB12706.1.3 adopts international electrician committee IEC60502
II. Working Features:
1. Environment temperature should be no lower than 0 for laying, the cable fall without limitation
2. The min bending radius of cable is stipulated as follows: Single core: 20(d+D) 5% three cores: 15(d+D) 5% (D is actual diameter of cable; d is actual outer diameter of conductor).
3. Operation temperature of cable PVC sheath is no more than 90.
4. Max rated temperature of cable conductor is 90 , and no higher than 250 in time of short circuit (max. Lasting time is no longer than 5s).
 
Our company can produce both flame retardant and non-flame retardant series of XLPE power cable.. Our products can be produced according to our works specifications which are equivalent to GB12706, IEC60502, IEC60332, IEC60754, and its some indexes are superior to standards stated above..
The flame-retardant cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three classes of A, B, C. We can design and manufacture special XLPE cable according to the other standards require by the customers, such as heavy section cut part conductors, water-resistant, defend termites, defend mouse, and so on..
 
Type
Description
Main Application
Cu core
Al core                
(ZR)YJV
or
(ZR)YJY
(ZR)YJLV
or
(ZR)YJLY23
(Flame retardant) Cu, Al core XLPE insulated, PVC or PE sheathed power cable.
For laying indoor, tunnel, underground and canal. Unable to bear external mechanical pulling force and pressure during laid.
(ZR)YJV22
or
(ZR)YJY23
(ZR)YJLV22
or
(ZR)YJLV23
(Flame retardant) Cu, Al core XLPE insulated, steel armoured, PVC or PE sheathed power cable.
For laying indoor, tunnel, underground and canal. Able to bear external mechanical pulling force , but unable to bear large pulling force.
(ZR)YJLV32
or
(ZR)YJLV33
(ZR)YJLV32
or
(ZR)YJLV33
(Flame retardant) Cu, Al core XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable
For laying in shaft, water under ground and large difference of level, able to bear mechanical pressure and moderate pulling force.
(ZR)YJLV42
or
(ZR)YJLV43
(ZR)YJLV42
or
(ZR)YJLV43
(Flame retardant) Cu, Al core XLPE insulated, thick steel wire armoured, PVC or PE sheathed power cable
For laying in the water, seabed and large difference of level, able to bear large mechanical pressure and pulling force..