CONTROL CABLE
1.Applications
1.Applications
PVC insulated and sheathed control cable is suitable for connecting wires between electrical equipments in controlling , monitoring loop and protecting circuit at rated voltage up to and include 450/750V(A.C.)
2.Standards of products
We can manufacture in accordance with the strandards of GB9330-88 or IEC227-1979,It can also be produced according to special requirements put forward by clients.
3.characteristics of using
a. AC rated voltage: 450/750KV
b. The maximum working temperature: PVC (PE) insulation does not exceed 70 oC
c. Minimum ambient temperature: PVC jacket: fixed installation -40 oC,non-fixed installation -15 oC
d. Cable laying temperature should not be less than 0 oC
e. Cable to allow bending radius: non-sheathed cables Cable diameter minimum of 6 times the Copper belt block or steel armored cable a minimum of 12 times the cable diameter.
a. AC rated voltage: 450/750KV
b. The maximum working temperature: PVC (PE) insulation does not exceed 70 oC
c. Minimum ambient temperature: PVC jacket: fixed installation -40 oC,non-fixed installation -15 oC
d. Cable laying temperature should not be less than 0 oC
e. Cable to allow bending radius: non-sheathed cables Cable diameter minimum of 6 times the Copper belt block or steel armored cable a minimum of 12 times the cable diameter.
Production Range
Type
|
Nominal cross-section (mm2)
|
||||||||
0.5
|
0.75
|
1.0
|
1.5
|
2.5
|
4
|
6
|
10
|
||
Number of cores
|
|||||||||
KVV
|
KYJV
|
- -
|
2 ~61
|
2 ~14
|
2 ~10
|
||||
KVVP
|
KYJVP
|
||||||||
KVVP2
|
KYJVP2
|
4 ~61
|
4 ~14
|
4 ~10
|
|||||
KVVP3
|
KYJVP3
|
7 ~61
|
4 ~61
|
||||||
KVV22
|
KYJV22
|
||||||||
KVVR
|
KYJVR
|
4 ~61
|
- -
|
||||||
KVVRP
|
KYJVRP
|
4 ~48
|
|||||||
Recommended number of cores:2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52 and 61.
|
Type of Cable
Type
|
Detailed Description of Type
|
Scope of utility
|
|||
PVC insulated
|
XLPE insulated
|
Flame-retardant Type
|
|||
PVC insulated
|
XLPE insulated
|
||||
KVV
|
KYJV
|
ZR-KVV
|
ZR-KYJV
|
PVC sheathed control cable
|
For laying indoors,in tunnels,or cable trench,or direct in ground.
|
KVVP
|
KYJVP
|
ZR-KVVP
|
ZR-KYJVP
|
PVC sheathed copper wire braid shield control cable
|
For laying indoors,in tunnels,or cable trench, direct in ground,stationary places needing shield
|
KVVP2
|
KYJVP2
|
ZR-KVVP2
|
ZR-KYJVP2
|
PVC sheathed copper tape wrapped shield control cable
|
|
KVVP3
|
KYJVP3
|
ZR-KVVP3
|
ZR-KYJVP3
|
PVC sheathed Al/Plastic wrapped shield control cable
|
|
KVV22
|
KYJV22
|
ZR-KVV22
|
ZR-KYJV22
|
PVC sheathed double steel tape armored control cable
|
For laying indoors,in tunnels,or direct in ground,be able to bear external mechanical force and certain pulling force.
|
KVVR
|
KYJVR
|
ZR-KVVR
|
ZR-KYJVR
|
PVC sheathed flexible control cable
|
For laying indoors,mobile place requiring softness (and shield).
|
KVVRP
|
KYJVRP
|
ZR-KVVRP
|
KYJVRP
|
PVC sheathed copper wire braid shield flexible control cable
|
|
Remarks:when flame-retardant types to be identified ,the code ZR should be changed into ZA,AB,ZC
|