1.Application
JSK4-d range air time-delay contactor relay is used in 50Hz(or 60Hz),rated voltage up to 380V or DC voltage up to 220V automatic control circuit, for time-delay components, and making or breaking circuit in forecast time .
2.Type and character
 structure feature
Relay is the modular structure; JSK4-d is arranged by JZC3-22d contactor way relay and SK4-d range air time-delay terminal. JSK4 is arranged by JZC3-22 contactor way relay and SK4 range air time-delay terminal, all accord air damping theory, use powder metallurgy unit as air filters, regulate knobs, and then continuously change time-delay value.
Coil voltage
24
48
110-120
220-240
380
JSK4-d
50HZ
/
/
/
/
Q
50/60HZ
B7
E7
F7
M7
/
 Character
Dynamic way
Making time-delay
Breaking time-delay
Time-delay connect point
1NO+1NC
Product structure
1NO+1NC
Product structure
connect point
2NO+2NC
2NO+2NC
Time-delay
area
0.1-3s
Jsk4-220d
JZC3-22D+SK4-220d
JSK4-320d
JZC3-22D+SK4-320d
0.1-30s
Jsk4-222d
JZC3-22D+SK4-222d
JSK4-322d
JZC3-22D+SK4-322d
10-180s
JSK4-224d
JZC3-22D+SK4-224d
JSK4-324d
JZC3-22D+SK4-324d
 3.Working and installation condition
 Ambient temperature: -25°C~+60°C;
 Elevation≤3000m;
 Relative humidity is not exceeding 85% at the maximum ambient        
temperature +40°C. Should give consideration to the dews, which would  
appear due to temperature change;                                                                                                                                                               Vibration condition: relay should be installed at the place without significantly shaken, shock and vibration.
Installation gradient: the tilt gradient with vertical face should ≤5°, can installed by screw or rail track;
Pollution grade: Grade 3;
Installation categories: class Ⅱ;
marine relay Ambient temperature: -25°C~+60°C;
Air condition: be able to bear the influence of moisture in the air,salt fog,oil fog,mould,humid air on the sea.
Tilt: all direction should low than 22.5°
Vibration: all direction should low than 22.5°
Shock: can bear frequency 2-13.2Hz and amplitude in ±1mm or frequency 13.2~80Hz and acceleration ±7m/s2
Power voltage and frequency changes: steady-state voltage is +6%~-10% of rated voltage, steady-state frequency change is ±5% or rated frequency.
The inclined angle between the mounting surface and vertical surface no more than 5° .
4. Production line
 
 
 
 
 
Raw materials testing
 
Plastic shell processing
 
Coil winding processing
 
Magnet processing
 
Spring winding
 
 
Metal parts processing
 
 
 
Product assemble
 
 
 
Product testing