HID manufacturer, apply imported components for high quality.
process of testing:
open circuit protection/short circuit protection/short voltage protection/over voltage protection/flash impact test/shockproof test/warm star-up test/waterproof/dustproof test/polarity protect test/EMC anti-jamming test/high/low temperature condition/operating test(-40°C to +105°C)
electrical input:
steady state input voltage:9-16V
max in rush current:15A @50ms,8A at 2secs
decreasing to steady state within 30 secs
max steady state input power:45W(9-16V)
input turn on: 9V and above
input turn off: below 8V]
reverse voltage protection: no damage to ballast under 40V
conducted EMI susceptibility:S95/54/EC
conducted EMI emission:S95/54/EC
efficiency: over 90% during steady status
guarantee:14 months