Manvac technik limited air Blower Maintenance

Cleaning: When dust or residue is evident, clean the entire surface of the blower.
Lubrication: After approximately 20,000 hours of operation, or 18 months, replace the grease in the bearings.
Installation

Units can be installed and mounted in any axial direction. For quiet and vibration-free operation, install the unit over a rubber pad. 
Do not obstruct the cooling system of the motor. Keep all ventilation gratings open and clear. Minimum clearance (1.5") 
must be maintained between the unit and all side walls or other barriers. 
Keep all flammable gases and materials away from the unit. 
After installation be sure to tighten the eye-bolt. The system voltage and frequency is the same as stated on the rating plate +/-5% voltage and/or +/-2% frequency deviation from the rated value without reducing output. Connections should be arranged and 
attached according to the circuit diagram on the terminal box.