1. Application
GSJ3 range contactor type relay is used in rated insulation voltage 690V, arrange of genenate heat current is up to 10A in AC 50Hz (or 60Hz), rated voltage up to 660V or DC voltage up to 400V circuit, for control variety electromagnetic coil, expanding or transmission signal.
2. Type
|
Power frequency
|
Coil voltage
|
|||||
|
24
|
36
|
48
|
110
|
220
|
380
|
|
|
50hz/60hz
|
B7
|
C7
|
E7
|
F7
|
M7
|
Q7
|
3. Structure feature
Direction-moving, double breaking contact terminal;
Can add installation F3-X (or F3-d) or air time-delay SK4-d on above; both sides can be fixed auxiliary contact arrangement F3-X1 (or F3-d1);
Products, compact, dust-proof performance, streamline appearance was designed to look generous.
4. Working and installation condition
Ambient temperature: -25° C~+60° C;
Elevation≤ 3000m;
Relative humidity is not exceeding 85% at the maximum ambient
temperature +40° C. Should give consideration to the dews, which would
appear due to temperature change;
Pollution grade: Grade 3;
Installing grade: class Ⅲ;
The tilt and swing gradient≤ 25°
Mounting way: mounted on screw or with TH3.5-7.5 standard rail;
5. Production line
Raw materials testing
Plastic shell processing
Coil winding processing
Magnet processing
Spring winding
Metal parts processing
Product assemble
Product testing