Measured media
|
Gas or liquid which will not corrode the 316 stainless steel
|
Types of pressure
|
Absolute pressure,sealed reference pressure,vented gauge pressure
|
range
|
-100kPa~0~10kPa~1MPa…10MPa…260MPa is optional
|
Power supply
|
24VDC(10-32VDC)
|
Output signal
|
4-20mA , 1-5VDC, 0-5VDC, 0-10VDC, 0.5-4.5 VDC is optional
|
Frequency response
|
≤1kHz(representative value)
|
repeatability
|
0.05%FS
|
nonlinearity
|
0.2%FS, 0.1%FS, 0.05%FS is optional
|
Comprehensive accuracy
|
0.1%FS, 0.2%FS, 0.5% FS is optional
|
Long-term stability
|
0.2%FS/year(representative value)
|
Operation temperature
|
-40~85℃/125℃/150℃/250℃ is optional(if adding water-cooled structure,can bear1200℃)
|
Insulation resistance
|
≥500 MΩ/100VDC
|
Safety overload pressure
|
150%FS (1.5 times full range)
|
Burst pressure
|
300%FS (3 times full range)
|
vibration
|
5~1000Hz, amplitude 2mm, X, Y, Z each direction 30 minutes, output variation is under 0.1%FS
|
impact
|
50g; X, Y, Z three directions, each direction 20ms; output variation is under 0.1%FS
|
Connection method
|
M20×1.5, M16×1.5, M14×1.5, M12×1, G1/4, G1/2, 1/4NPT, 1/2NPT or named
|
Wetted material
|
Diaphragm:17-4PH stainless steel,process connection:1Cr18Ni9Ti
|
Relative humidity
|
0~95% RH
|
Protection rate
|
IP65, IP67 is optional
|
Outlet method
|
Air plug,directly leading
|
Control instrument
(optional)
|
CPM-TC1C6(accuracy:0.5%), CPM-TC1CT(accuracy:0.2%), CPM432-TC1(accuracy:0.05%)
|