CWT5002-1 MODBUS GPRS RTU enables various kinds of devices with I/O and Standard MODBUS protocols to communicate over GSM/GPRS network and the Internet easily and freely. It can construct a smooth “GPRS Data Tunnel” between Host End and Remote End, ensuring an efficient communication for data transmission and remote device management. It also support send user-defined alarm sms when pre-defined alarm condition happens, and can be controlled via SMS command.
With 4 Digital Inputs and 4 drivable Outputs, 1 selectable RS-232/485 serial port connect slave to read and writer 32 registers, CWT5002-1 is an ideal solution for factory automation, environmental monitoring and remote device management for M2M industry.
 
Monitor 32 registers on modbus + 4DI + 4DO + GPRS transmission + sms alarm/control
 
Feature
Advance features
·Adopted highly integrated industrial CPU
·Easy used GUI configure software
·Reliable performance with built-in double watchdog
·Low maintenance, 24×7 operation
·Support ring call when alarm
·Temperature sensor (optional)
·Internal battery and providing power cut off alarm
 
4 digital inputs feature
·Upload data when inputs are triggered
·Upload input status on schedule
·Can be reuse as pulse counter input
·SMS alarm when inputs are triggered
·NO or NC type can be preset
·Configurable for alarm and recover sms
·Remote query inputs status
 
4 relay drivable outputs feature
·Multiple output type can be preset
·Remote On/Off/Pulse outputs via GPRS or sms
·Configurable for pulse time
·Remote query outputs status via GPRS or sms
·Outputs can be activated by alarm or call
·Outputs can be activated on schedule
 
Modbus feature
·Modbus RTU protocol on RS232 or RS485, monitor modbus slave
·Read or write 32 registers (coil or input registers) on Modbus via GPRS or SMS
·Upload data to server when coils are triggered
·Can preset normal range for input registers; upload data to server when above the normal range
·Support SMS operation (read or write registers)
 
GPRS feature
·Support connects 4 servers, the servers must connect internet and have static public IP address or Dynamic Domain name
·GPRS Transmission base on TCP/IP
·Support modbus TCP protocol
 
Specifications
Parameter item
Reference scope
DC Power supply
12-24V DC (Standard adapter: DC 12V/1.5A)
Power consumption
12V input  Max. 150mA/Average 50mA
Frequency range
Quad-frequency 900/1800/850/1900HMz
SIM Card
Supporting 3V SIM Card
Antenna
50 Ω SMA Antenna interface
Serial port
Selectable RS-232/485
Temperature range
-30°C ~ +70 °C
Humidity range
Relative humidity 95%
Digital Input
4 digital inputs(Dry contact)
output
4 drivable relay outputs(open-collector outputs)
Output drive voltage
Equal to input DC voltage
Output drive power
Drive voltage ≤35V, drive current ≤500mA
Exterior dimension
95×63×25mm
Weight
256 g
 
The GPRS Modbus RTU CWT5002-1 supports 4 I/O port monitoring by Modbus TCP Protocol over GPRS. It can be connected to various transducers like pressure transducer, oil level transducer, current transducer, voltage transducer, temperature transducer and so on. Also it can be connected to digital detectors and digital outputs.
The GPRS Modbus RTU CWT5002-1 supports transparent and non-transparent data transfer by RS485 and RS232 over GPRS. It can be connected to intelligent instrument and industrial meters directly to read the values of analog input, TTL, digital input, pulse counter and so on.
The GPRS RTUsuitable for below applications:
◆The Electricity Power Industry
1.    Remote Meter Reading
2.    Power monitoring
3.    Streetlight monitoring
4.    Meter monitoring
5.    Control Room monitoring
6.    Power distribution automation remote control systems
◆Automatic monitoring system
◆Vending Machines,ATM,POS
◆The traffic Industry
1.     Traffic instructions
2.     Vehicle Park Guide
3.     Expressway monitoring
4.     Traffic lights control and photograph transmission
◆Water Industry
1.    Water Monitoring
2.    Water Meter Reading
3.    Real-time transmission of the water supply network monitoring
◆Environment , meteorology, oil and other industries
1.     Environmental protection of key pollution sources monitoring
2.     Environmental monitoring
3.     Meteorological monitoring
◆The noise real-time monitoring
◆Oilfield monitoring
◆Heating network monitoring
◆Coal monitoring
◆Seismic monitoring
◆All kinds device with RS232 serial port or RS485 of the PLC, RTU wireless data transmission.