Overview:
Pressure building liquid nitrogen container (Dewar) generates pressure by evaporation of a small amount of liquid nitrogen, so that the container can discharge liquid nitrogen automatically, and supply liquid nitrogen for other containers. It finds its application in the transportation and storage of liquid medium and cold source of other refrigeration equipments. It is now widely used in tool and die industry, animal husbandry, medicine, semi-conductor, food, cryogenic chemical industry, aerospace, military and other industries and areas.
Production Standard: GB16774-1997(Pressure Building Liquid Nitrogen Container)
Production Technology: Inner and outer shells of the main body are made of 304 austenite cryogenic stainless steel of fine quality; absorbents are regenerated and activated; multi-layer insulation materials are oil-and-lipid-free thin imported composite. All welds are qualified by helium mass spectrometer leak detection; 100% of products have gone through strict cryogenic testing; unique neck design ensures a very low rate of evaporation losses; machine or digital display liquid level gauge is optional; The surface of the container using a unique polishing technology, and has aesthetic modeling.
Security Technology:
A two-way multi-level security system is installed to ensure the safe and reliable use of the product; the layout of valve interface is reasonable for secure and convenient operation.
Specifications | Unit | YDZ-5 | YDZ-15 | YDZ-30 | YDZ-50 | YDZ-100 | YDZ-150 | YDZ-175 | YDZ-200 | YDZ-300 | YDZ-500 |
Geometric volume | L | 5.5 | 16.5 | 32 | 55 | 110 | 165 | 185 | 220 | 330 | 550 |
Effective volume | L | 5 | 15 | 30 | 50 | 100 | 150 | 175 | 200 | 300 | 500 |
Outside diameter | mm | 325 | 400 | 450 | 500 | 600 | 650 | 700 | 750 | 850 | 1000 |
Height | mm | 550 | 725 | 885 | 970 | 1175 | 1200 | 1250 | 1300 | 1400 | 1500 |
Weight empty | Kg | 15 | 23 | 32 | 54 | 75 | 102 | 120 | 130 | 202 | 255 |
Neck tube diameter | mm | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
Daily evaporation rate | % | 3 | 2.5 | 2.5 | 2 | 1.3 | 1.3 | 1.2 | 1.2 | 1.1 | 1.1 |
Standard working pressure | Mpa | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 |
Maximum working pressure | Mpa | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 |
Liquid velocity | L/min | ≥2 | ≥2 | ≥3 | ≥4 | ≥4 | ≥4 | ≥4 | ≥4 | ≥4 | ≥4 |
Setting Pressure of the first safety valve | Mpa | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 | 0.099 |
Setting Pressure of the second safety valve | Mpa | 0.115 | 0.115 | 0.115 | 0.115 | 0.115 | 0.115 | 0.115 | 0.115 | 0.115 | 0.115 |
Pressure gauge indication range | Mpa | 0 ~ 0.25 | 0 ~ 0.25 | 0 ~ 0.25 | 0 ~ 0.25 | 0 ~ 0.25 | 0 ~ 0.25 | 0 ~ 0.25 | 0 ~ 0.25 | 0 ~ 0.25 | 0 ~ 0.25 |