Features
User friendly, easy and customized operation
Double MPU to ensure system security
Manual bolus but automatical antibolus to increase patient safety
Automatically recognize the syringe type-- 10ml/20ml/30ml/50ml/60ml, any brand after calibration
Up to 8 hours battery back up for single channel at the rate of 5ml/h, 6 hours for double channel,
4 hours for four channel
Ideally suitable for OT, ICCU, NICU, PICU etc
User friendly, easy and customized operation
Double MPU to ensure system security
Manual bolus but automatical antibolus to increase patient safety
Automatically recognize the syringe type-- 10ml/20ml/30ml/50ml/60ml, any brand after calibration
Up to 8 hours battery back up for single channel at the rate of 5ml/h, 6 hours for double channel,
4 hours for four channel
Ideally suitable for OT, ICCU, NICU, PICU etc
Specification
Channel: Single
Compatible syringe: 10ml 20ml 30ml 50/60ml
Infusion rate: 0.1-400ml/h, (50ml/60ml)
0.1-200ml/h, (20ml/30ml)
0.1-99.9ml/h, (10ml)
Purge rate/bolus rate/top infusion rate: 400ml/h; (50ml/60ml)
200ml/h; (20ml/30ml)
99.9ml/h; (10ml)
Volume limit: 0-999.9ml, Step by 0.1
Accuracy: +2%
Infusion Step by: 0.1ml/h
Visible & audible alarms: Syringe dislocation, Near empty, Pause overtime, Low battery, VTBI completion, Power cord falling, Malfunction, Incorrect syringe type, Electrical circuit jam
Occlusion pressure: High 20ml\30ml\50ml/60ml Syringe Space: 90kpa+30kpa
10ml Syringe Space: 100kpa+30kpa
Occlusion pressure: Low 20ml\30ml\50ml/60ml Syringe Space: 50kpa+30kpa
10ml Syringe Space: 70kpa+30kpa
KVO rate: 0.1ml/h+0.02ml/h
Power: AC: 100V-240V 50Hz/60Hz DC: 12V
Pause overtime alarm: 1min50s-2min
Appalled standards: ISO 13485 & CE Certified
Dimension: 290mm(L)*130mm(W)*130mm(H)
Weight: 2kg
Channel: Single
Compatible syringe: 10ml 20ml 30ml 50/60ml
Infusion rate: 0.1-400ml/h, (50ml/60ml)
0.1-200ml/h, (20ml/30ml)
0.1-99.9ml/h, (10ml)
Purge rate/bolus rate/top infusion rate: 400ml/h; (50ml/60ml)
200ml/h; (20ml/30ml)
99.9ml/h; (10ml)
Volume limit: 0-999.9ml, Step by 0.1
Accuracy: +2%
Infusion Step by: 0.1ml/h
Visible & audible alarms: Syringe dislocation, Near empty, Pause overtime, Low battery, VTBI completion, Power cord falling, Malfunction, Incorrect syringe type, Electrical circuit jam
Occlusion pressure: High 20ml\30ml\50ml/60ml Syringe Space: 90kpa+30kpa
10ml Syringe Space: 100kpa+30kpa
Occlusion pressure: Low 20ml\30ml\50ml/60ml Syringe Space: 50kpa+30kpa
10ml Syringe Space: 70kpa+30kpa
KVO rate: 0.1ml/h+0.02ml/h
Power: AC: 100V-240V 50Hz/60Hz DC: 12V
Pause overtime alarm: 1min50s-2min
Appalled standards: ISO 13485 & CE Certified
Dimension: 290mm(L)*130mm(W)*130mm(H)
Weight: 2kg