Product Main

Specifications

Neurocare-A trolley EMG/EP system is a modular designed EMG/EP system, It integrates modules of 1CH/2CH/4CH amplifier, Acoustic& Visual stimulator, Current stimulator to do EMG, NCV and EP examination. Configured with flexible operation panel, foot switch and optional streamlined trolley, It's a perfect system to do nerve and muscle examination in Neurology department and Neurosurgery department.
Features
1. Transmission and Anti-interference: 
Fiber optical transmission between pre-amplifier and core unit ensure strong anti-interference capability, it also guarantee stable and reliable signal transmission with strong anti-interference capability. 
2. USB 2.0 interface: 
It's able mount with laptop or desktop, realize high-speed and secure data transmission. 
3. Modular design: 
Enables different combinations for different examination. It's convenient for transportation and maintenance. 
4. Multi-lingual software and can be updated for free lifelong
Realize language conversion easily and can support convenient application in different language environment. 
5. Humanization and strong capability of upgrade
Available ability to upgrade: 8/16 introperative monitor, suface EMG function and ASSR function.
Specification: 
Channels: 1/2/4; Dual-fiber signal transmission isolation 
Sensitivity: 0.05μ V/div -20 mV/div, 
Amplitude-frequency characteristic: 1Hz~5kHz, 
Noise: ≤ 0.4μ V (VP-P)
Impedance: > 1000MΩ 
CMRR: ≥ 110dB
Gain Amplifier: 50 times ~ 50 million times
Max higher filters frequency: 50Hz
Min Lower filters frequency: 0.1Hz
Control Part
A / D conversion rate: 24Bit
Sample Rate: 200 kHz
Stimulus frequency: 0.1-50 Hz
Analysis time: 1-1000ms
Splice time: 1-5000times
Current Stimulation 
Current intensity output range: 0 ~ 100mA, error ≤ ± 10%
Stimulus modes: Single-current stimulator, dual-current stimulator
Stimulus frequency: 0.1 Hz ~ 100Hz, error ≤ ± 10%
Stimulus width: 50us_1000us
Pulse duration error: 0.05ms, 0.1ms, 0.5ms, 1ms, Error ≤ ± 10%
Pulse mode: Single pulse, double pulse, three pulses. 
A/V Stimulation
Sound 
Stimulus intensity: 30~120 dB
Stimulus frequency: 0.1~20H
Stimulation method: Rare wave, dense wave, alternative wave
Pictures 
Pattern mode: Checkerboard, vertical grid, bar grid
Image Size: 64 * 32, 32 * 24, 16 * 12, 8 * 6, 4 * 4
Vision: Full vision, half-field (left), 1 / 4 view (I, II, III, IV quadrant)
Stimulation frequency: 1 ~ 20 times / sec
Flash
Stimulus frequency: 0.1 ~ 20Hz adjustable;
Software functions(Examination Protocols):
Electromyography (EMG): 
Motor Unit Potential (MUP)
Interference phase(IP) 
Scanning EMG
Evoked potential (EP): 
Somatosensory Evoked Potential (SEP): 
USEP; LESEP; TSEP; SCEP
Acoustic evoked potential (AEP) 
BAEP, MAEP, LAEP, EoochG, 40Hz
Visual evoked potential (VEP)
PRVEP, FVEP, ERG, EOG
Nerve Conductive Studies (NCV)
Motor NCV (MCV)
Sensory NCV (SCV)
Short segment conduction (SSCT)
Repetitive nerve stimulation (RNS)
F-wave; 
H-reflex; 
Blink Reflex (BR)
Sympathetic Skin Response (SSR)