Product Main

Specifications

automatic voltage regulator price air conditioner stabilizer SVC-3KVA 3000W 220V

Technology  Servo motor control
 Display   Meter Output voltage/input voltage
Light Green Normal woking
Red Over voltage
Yellow Delay time  Long time:3~8M Short time:5seconds
Protection high voltage Output voltage≥248±4V
low voltage Output voltage≤170±4V
over temperature 120℃±10℃
Input voltage AC150V-270V
Output voltage 220V±3% adjustable
Frequency 50/60Hz
Phase Single Phase 
Effiency ≥90%
Ambient temperature -15℃~45℃ 
Relative humidity <95%   
Waveform distortion no additional waveform form distortion
Insulating resistance Normally more than 2MΩ



Voltage regulator selection method

When you want to select regulator,you should calculate th sum of ll load powers,to avoid over load,and when you calculate that,if they are freezer,refrigerators,you must remember to use power times finve,if they are air conditioning,air condtioners, you can use power  times 3,and to other inductive olad you can use power tmes 2, according to the calculation of the total power then to choose the appropriate size of the regulator.

If the voltage of mains voltage always less than 160V,you can multplied by 1.8 when calculating total power,so to insure it can also have excellent load characteristics during the voltage is low.