7"color TFT screen Multi‐channel display Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Technical Specifications
ECG
Alarm review, arrhythmia review Patient info. Input Anti‐defibrillation design
NIBP over pressure protection
Li-ion batteries, detachable and rechargeable , continuous working 90 minutes;, AC/DC adaptable:12V3A 100v-240v
Supporting wire network.
NIBP
Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) Lead selection I, II, III, avR, avL, avF, V,
Wavefo rm 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL) Lead selection I, II, III,
Wavefo rm 1 ch
Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,
20mm/mV, auto
HR and Alarm Range Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy ±1% or 1bpm,which is greater 1 bpm
ResolutionSensitivity > 200 (uV P‐P)
Differential Input Impedance > 5 M
CMRR Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After
Defi. ECG Signal Range 8 mV ( Vp‐p ) Bandwidth Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 300 Hz
Calibration Signal 1 (mV p‐p), Accuracy 5%
ST Segment Monitoring Range Measure and Alarm ‐2.0 ~ +2.0 mV
ARR Detecting Type: Asystole, ventricular, fibrillation, ventricular tachycardia, pacer non-capture, ventricular rhythm, couplet, VT>2, Bigeminy, trigeminy, Ron T PVC, Multiform PVC, irregular rhythm, missed beats, bradycardia, tachycardia
Respiration
Method Impedance between R‐F(RA‐LL) Differential Input Impedance >2.5 M
Measuring Impedance Range 0.3~3.0
Base line Impedance Range 0 ~4K Bandwidth 0.1~ 2.5 Hz
Resp. Rate Measuring and Alarm Range
Adult0 ~ 120 rpm
Neo/Ped0 ~ 150 rpm
Resolution 1 rpm Accuracy ±2 rpm Apnea Alarm 10 ~ 40 S
Method Oscillometric
Mode Manual, Auto, Continual
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm Alarm Type SYS, DIA, MEAN Measuring and alarm range Adult Mode
SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg
Resolution 1mmHg
Accuracy Maximum Mean error ±5mmHg
Maximum Standard deviation 8mmHg
Overpressure Protection Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147± 3mmHg
SpO2
Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 0 ~ 100 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec
Alarm Delay 10 Sec
Pulse Rate Measuring and Alarm Range 20~300bpm
Resolution 1bpm
Accuracy ±3bpm
TEMP
Channel 1
Measuring and Alarm Range 0 ~ 50
Resolution 0.1
Accuracy ±0.2
Actualization interval about 1 Sec
Average Time Constant < 10 Sec
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional: EtCO2
|