Product Main

Specifications

Introduction
Every model has a corresponding frequency conversion compressor, which controls the air delivery by changing the rotational speed of motor, making the air output and electricity consumption smoothly vary the air supply decreases and so does the electricity consumption for energy conservation. For capacity ranging from 2 to 60m3/min and discharge pressure from 0.5-1.3Mpa. There are corresponding models available to customers with different requirements.
In addition to that frequency conversion air compressors have the same good quality as other ERC model, the quality frequency converter will further better the result of energy conservation. With the help of the PID regulator disposed in frequency converter, it can start up smoothly, causes little impact on the power grid and generates great low-frequency start moment of current vector control and small running current. When the air use decreases, the compressors enter the sleeping status, saving considerable energy. Moreover, digital to analog conversion is highly accurate and the integration design features few fault points. 
 
Life of compressor air end:
Rotors are asymmetric in profile and backed up by ball bearings and roller bearings and operate at a low speed. Helical gears can produce axial force to kill some acting force, which reduces the load of the bearing of compressor air end. Thereby low in abrasion and maintenance and repair expenses and the compressor air end being long in service life. 
 
More reliable operation:
With frequency conversion soft start reduce in-rush starting current, reduce wear on electrical switch gears and motor windings. Also maintain less power during starting and stopping of motors and increase protection to motors. Also reduce peak demand and improve power factor.
 
In the case of rated power license setting desired pressure at discretion, and maintaining constant pressure at discretion, and maintaining constant pressure:
User to choose any delivery pressure between 4-13bar without any gears or belt change. When the use of air increases the unit increases air output through automatic acceleration of rotational speed to avoid a falling pressure and ensure volume at constant pressure. When the use of air decreases, the unit reduces air output by automatically lowering the rotational speed to avoid pressure increase and ensure continued air supply constant pressure.
 
Efficiency and energy conservation:
Thanks to the variable-speed control technology, the capacity of compressors can be perfectly combined with the air use of users, which downright avoid the unloading power loss. In intermittent air use, the minimized load of soft start eliminates the starting frequency of the peak current and further smooth start can reduce the power supply, equipment costs as well as the impact on the network power.


Model
ERC-15SA
ERC-20SA
ERC-25SA
ERC-30SA
ERC-30SW
ERC-40 SA
ERC-40SW
ERC-50SA
ERC-50SW
ERC-60SA
ERC-60SW
ERC-75SA
ERC-75SW
ERC-100SA
ERC-100SW
ERC-120SA
ERC-120SW
Type of cooling
                                                        A-Air cooling    W-Water cooling
Air deliver/
Working pressure
m3/min/bar
0.68-1.7/7
0.96-2.4/7
1.24-3.1/7
1.52-3.8/7
1.52-3.8/7
2.08-5.3/7
2.08-5.3/7
2.56-6.6/7
2.56-6.6/7
3.2-8.0/7
3.2-8.0/7
4.2-10.5/7
4.2-10.5/7
5.4-13.6/7
5.4-13.6/7
6.4-16.2/7
6.4-16.2/7
0.64-1.65/8
0.88-2.2/8
1.16-2.9/8
1.4-3.6/8
1.4-3.6/8
2.0-5.0/8
2.0-5.0/8
2.4-6.2/8
2.4-6.2/8
3.08-7.7/8
3.08-7.7/8
3.92-9.8/8
3.92-9.8/8
5.16-13.0/8
5.16-13.0/8
6.16-15.4/8
6.16-15.4/8
0.56-1.5/10
0.84-2.1/10
1.08-2.7/10
1.28-3.2/10
1.28-3.2/10
1.72-4.3/10
1.72-4.3/10
2.2-5.7/10
2.2-5.7/10
2.6-6.9/10
2.6-6.9/10
3.4-8.7/10
3.4-8.7/10
4.4-11.3/10
4.4-11.3/10
5.6-13.2/10
5.6-13.2/10
0.481.3/12.5
0.68-1.8/12.5
0.88-2.3/12.5
1.08-2.5/12.5
1.08-2.5/12.5
1.48-3.6/12.5
1.48-3.6/12.5
1.84-4.6/12.5
1.84-4.6/12.5
2.16-6.0/12.5
2.16-6.0/12.5
2.84-7.3/12.5
2.84-7.3/12.5
3.7-10.1/12.5
3.7-10.1/12.5
4.6-11.2/12.5
4.6-11.2/12.5
Motor power
KW
11
15
18.5
22
22
30
30
37
37
45
45
55
55
75
75
90
90
Voltage/frequence
V/Hz
AC 380V/50Hz
Starting method
Variable frequency starting
Noise
dB(A)
72±5, tested according to the international standard GB/T4980-2003
Oil content of discharge air
<3 ppm
Outlet air temperature
Ambient temperature + 15 ℃
Cooling air volume
m3/min
50
50
110
110
 
145
 
145
 
185
 
220
 
250
 
270
 
Cooling water volume
L/min
 
 
 
 
14.5
 
20
 
25
 
30
 
39.9
 
51
 
61
Pipe connection diameter
1”
1”
1”
1”
1”
1 1/4”
1 1/4”
1 1/4”
1 1/4”
1 1/2”
1 1/2”
2”
2”
2”
2”
2”
2”
Weight
Kg
460
460
645
655
655
925
925
1110
1110
1210
1210
1810
1810
1900
1900
2190
2190
Dimension(mm)
L
1150
1150
1200
1200
1200
1250
1250
1450
1450
1500
1500
2100
2100
2100
2100
2100
2100
W
700
700
850
850
850
900
900
1000
1000
1000
1000
1320
1320
1320
1320
1320
1320
H
1180
1180
1280
1280
1280
1360
1360
1465
1465
1480
1480
1700
1700
1700
1700
1700
1700


Model
ERC-150SA
ERC-150SW
ERC-175 SA
ERC-175 SW
ERC-200SA
ERC-200SW
ERC-250SA
ERC-250SW
ERC-270SA
ERC-270SW
ERC-300SA
ERC-300SW
Type of cooling
                                                        A-Air cooling    W-Water cooling
Air deliver/
Working pressure
m3/min/bar
8.32-20.8/7
8.32-20.8/7
9.6-24.0/7
9.6-24.0/7
11.08-27.8/7
11.08-27.8/7
13-32.5/7
13-32.5/7
13.6-34.5/7
13.6-34.5/7
14.8-38.0/7
14.8-38.0/7
7.8-19.5/8
7.8-19.5/8
9.2-23.0/8
9.2-23.0/8
10.2-26.0/8
10.2-26.0/8
12.4-31.0/8
12.4-31.0/8
12.8-33.0/8
12.8-33.0/8
14.0-36.5/8
14.0-36.5/8
6.3-16.5/10
6.3-16.5/10
7.4-20.0/10
7.4-20.0/10
9.0-23.5/10
9.0-23.5/10
9.8-26.0/10
9.8-26.0/10
11.2-28.0/10
11.2-28.0/10
12.032.0/10
12.032.0/10
5.2-13.7/12.5
5.2-13.7/12.5
5.8-15.5/12.5
5.8-15.5/12.5
7.32-19.5/12.5
7.32-19.5/12.5
8.0-21.6/12.5
8.0-21.6/12.5
9.4-23.5/12.5
9.4-23.5/12.5
10.4-27.0/12.5
10.4-27.0/12.5
Motor power
110
110
132
132
160
160
185
185
200
200
220
220
Voltage/frequence
AC 380V/50Hz
Starting method
Variable frequency starting
Noise
 
72±5, tested according to the international standard GB/T4980-2003
Oil content of discharge air
<3 ppm
Outlet air temperature
Ambient temperature + 15 ℃
Cooling air volume
m3/min
420
 
460
 
510
 
510
 
620
 
710
 
Cooling water volume
L/min
 
79
 
91
 
105
 
123.5
 
131
 
144
Pipe connection diameter
DN65
DN65
DN65
DN65
DN65
DN65
DN80
DN80
DN80
DN80
DN100
DN100
Weight
Kg
3030
3030
3320
3320
3720
3720
3930
3930
4550
4550
5080
5080
Dimension(mm)
L
2545
2500
2545
2500
2650
2650
2650
2650
2850
2850
3400
3400
W
1450
1550
1450
1550
1550
1550
1550
1550
1700
1700
1950
1950
H
1900
1900
1900
1900
1920
1950
1920
1950
2000
2000
2020
2020


Model
ERC-330SA
ERC-330SW
ERC-375SA
ERC-375SW
ERC-420SA
ERC-420SW
Type of cooling
                                                        A-Air cooling    W-Water cooling
Air deliver/
Working pressure
m3/min/bar
17.2-43.0/7
17.2-43.0/7
21.0-51.5/7
21.0-51.5/7
21.6-56.0/7
21.6-56.0/7
16.2-40.5/8
16.2-40.5/8
20.0-50.0/8
20.0-50.0/8
18.8-55.0/8
18.8-55.0/8
13.6-36.5/10
13.6-36.5/10
18.0-45.0/10
18.0-45.0/10
15.6-49.0/10
15.6-49.0/10
12.0-32.0/12.5
12.0-32.0/12.5
14.8-37.0/12.5
14.8-37.0/12.5
13.4-41.0/12.5
13.4-41.0/12.5
Motor power
250
250
280
280
315
315
Voltage/frequence
AC 380V/50Hz 6K/50  10K/50
Starting method
Variable frequency starting
Noise
 
72±5, tested according to the international standard GB/T4980-2003
Oil content of discharge air
<3 ppm
Outlet air temp.
Ambient temperature + 15 ℃
Cooling air volume
m3/min
800
 
890
 
960
 
Cooling water volume
L/min
 
163
 
202
 
212
Pipe connection diameter
DN100
DN100
DN125
DN125
DN125
DN125
Weight
Kg
5700
5700
6500
6500
7850
7850
Dimension(mm)
L
3400
3400
4000
4000
4600
4600
W
1950
1950
2000
2000
2300
2300
H
2020
2020
2100
2100
2400
2400