Specifications
1 Low insertion loss, Low PDL and High reliability
2 High return loss and Good repeatability
3 Wide wavelength range
1 Description
PLC splitter adopts technology of integrated optics with splittering chip and lithography to
make lightwave circuit on Si based Silicon block or glass block, to realize optical multiple distribution.
It is widely used in FTTH,CATV,GPON,Test equipments.
2 Applications:
---LAN, WAN and Metro Networks
---FTTH project & FTTX Deployments
---CATV System
---GPON, EPON
--- Fiber Optic Test Equipment
---Data-base Transmit Broadband Net
3. Features
Good uniformity and low insertion loss
Low polarization dependent loss
Excellent Enviornmental Stability
Excellent Mechanical
Stability Telecordia GR-1221 and GR-1209
4. PLC Splitter specification (room temperature,without connector insertion loss)
Parameter
|
Specification
|
||||||||||||
Operating Wavelength(nm)
|
1260~1650
|
||||||||||||
Type
|
1*2
|
1*4
|
1*8
|
1*16
|
1*32
|
1*64
|
2*2
|
2*4
|
2*8
|
2*16
|
2*32
|
2*64
|
|
Insertion Loss(dB)
|
Typical
|
3.6
|
6.8
|
10.0
|
13.0
|
16.0
|
19.5
|
4.0
|
7.0
|
10.5
|
13.5
|
16.5
|
20.5
|
(P/S)Max
|
3.8/4.0
|
7.1/7.3
|
10.2/10.5
|
13.5/13.7
|
16.5/16.8
|
20.5/21.0
|
4.1/4.3
|
7.4/7.6
|
10.8/11.0
|
14.3/14.5
|
17.3/17.5
|
20.7/21.5
|
|
Uniformity(dB)
|
Typical
|
0.4
|
0.5
|
0.5
|
1.0
|
1.0
|
2.5
|
0.6
|
0.8
|
1.0
|
1.5
|
2.0
|
2.0
|
Max
|
0.6
|
0.6
|
0.8
|
1.2
|
1.5
|
2.5
|
0.8
|
0.8
|
1.5
|
2.0
|
2.5
|
2.5
|
|
PDL(dB)Max.
|
Typical
|
0.1
|
0.1
|
0.1
|
0.2
|
0.2
|
0.2
|
0.1
|
0.1
|
0.1
|
0.2
|
0.2
|
0.2
|
Max
|
0.15
|
0.15
|
0.25
|
0.3
|
0.3
|
0.3
|
0.2
|
0.2
|
0.3
|
0.4
|
0.4
|
0.4
|
|
Wavrelength department loss(dB)
|
Typical
|
0.1
|
0.1
|
0.1
|
0.1
|
0.2
|
0.2
|
0.1
|
0.1
|
0.1
|
0.1
|
0.2
|
0.2
|
Max
|
0.2
|
0.2
|
0.3
|
0.5
|
0.5
|
0.5
|
0.2
|
0.2
|
0.3
|
0.5
|
0.5
|
0.5
|
|
Temperature department loss(dB)
|
Typical
|
0.3
|
0.3
|
0.3
|
0.4
|
0.4
|
0.4
|
0.3
|
0.3
|
0.3
|
0.4
|
0.4
|
0.4
|
Max
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
|
Directivity(dB)Min
|
55
|
||||||||||||
Return Loss(dB)Min
|
55(50)
|
||||||||||||
Operating Temperature(°C)
|
-40~+85
|
||||||||||||
Storage Temperature(°C)
|
-40~+85
|
||||||||||||
Fiber Length
|
1m or client requirments
|
||||||||||||
Fiber Type
|
ITU G652.D /G657.A
|
||||||||||||
Connector Type
|