Product Main

Specifications

APC Pure Sine Wave Inverter, Charger
APC pure sine wave inverter is the latest model presented by Yiyuan Electric Co.,Ltd.. Developed on the base of our previous PSW 7 series, the APC charger has achieved significant improvements on battery charging, AC transfer, etc. By adopting DIP (dual in-line package) switch, the APC pure sine wave inverter provides more smart options for users to customize the performance of the device.
Features of APC Pure Sine Wave Inverter, Charger
1. High overload ability of our APC charger is up to 300% rated power(20 sec.).
2. APC pure sine wave inverter adopts low quiescent current, and power saver mode to reduce power consumption to 10W(3s sensing cycle)/3W(30s sensing cycle) *. It can extract max. power from various batteries with different protections, and low voltage trip can be selected (9.5V/10V or 10V/10.5V).
3. Uses PFC(power factor correction) for charger, which has less power consumption than conventional units.
4. It has 15s delay before transfer when AC resumes, and overload protection when our APC pure sine wave inverter equips with generator.
5. 10ms typical transfer time between battery and AC, which guarantees power continuity of APC charger. Uses selectable input AC voltage (184-253V or 154-253V) for different kinds of loads.
6. Our APC charger allows start up and through power with depleted batteries. Its powerful charge rate up to 90Amp**.
7. It can offer 3-step intelligent battery charging, and equipped with 8 preset battery type selector for totally flat batteries.
8. LCD status display, battery/AC priority switch, USB communication port are available for our APC pure sine wave inverter, it also has 17 alarms/warnings for easier operation and trouble-shooting, and ability to switch the unit on/off. In addition, select/deselect power saver mode can be used too.
Note:*For 1KW one. **For some models.

Technical Parameters of APC Pure Sine Wave Inverter, Charger
Electrical Specifications
  Model APC 1000W APC 1500W APC 2000W APC 3000W APC 4000W APC 5000W APC 6000W
Inverter Output Continuous Output Power 1000W 1500W 2000W 3000W 4000W 5000W 6000W
Surge Rating(20s) 3000W 4500W 6000W 9000W 12000W 15000W 18000W
Capable of Starting Electric Motor 1HP 1.5HP 2HP 3HP 4HP 5HP 6HP
Output Waveform Pure Sine wave/Same as input(Bypass mode)
Nominal Efficiency >88%(Peak)
Line Mode Efficiency >95%
Power Factor 0.9-1.0
Nominal Output Voltage rms 100-110-120Vac / 220-230-240Vac
Output Voltage Regulation ±10% RMS
Output Frequency 50/60Hz ± 0.3Hz
Short Circuit Protection Yes, Current Limit Function (Fault after 1sec)
Typical transfer Time 10ms(Max)
THD < 10%
DC Input Nominal Input Voltage 12.0Vdc
( *2 for 24Vdc, *4 for 48Vdc)
Minimum Start Voltage 10.0Vdc
Low Battery Alarm 10.5Vdc / 11.0Vdc
Low Battery Trip 10.0Vdc / 10.5Vdc
High Voltage Alarm & Fault 16.0Vdc
High DC Input Recovery 15.5Vdc
Low Battery voltage recover 13.0Vdc
Idle Consumption-Search Mode < 25 W when Power Saver On
Charge Input Voltage Range Wide: 90-135VAC / 164-243VAC;
Narraw: 100-135VAC / 194-243VAC;
Output Voltage Depends on battery type
Charger Breaker Rating 10A 10A 10A 20A 20A 30A 30A
Max Charge Rate 35A / 70-90A Max (Charger Current Control)
Over Charge Protection Shutdown 15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc)
Charger curve(4 stage constant current)
4 step digital controlled progressive charge
Battery types ( *2 for 24Vdc, *4 for 48Vdc)
Battery type Fast Vdc  Float Vdc
Gel U.S.A 14.0  13.7
A.G.M 1 14.1  13.4
A.G.M 2 14.6  13.7
Sealed Lead Acid  14.4  13.6
Gel Euro 14.4  13.8
Open Lead Acid 14.8  13.3
Calcium 15.1  13.6
De-sulphation 15.5 for 4hrs
Remote Control  Yes. Optional
Bypass & Protection Input Voltage Waveform Sine wave (Grid or Generator)
Nominal Voltage 120Vac 230Vac
Low Voltage Trip  80V/90V±4% 184V/154V±4%
Low Voltage re engage 90V/100V±4% 194V/164V±4%
High Voltage Trip 140V±4%  253V±4%
High Voltage re engage 135V±4% 243V±4%
Max Input AC Voltage 150VAC 270VAC
Nominal Input Frequency 50Hz or 60Hz (Auto detect)
Low Freq Trip 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
Low Freq re engage 48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz
High Freq Trip 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
High Freq re engage 54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz
Output Short circuit protection Circuit breaker
Bypass breaker rating 10A 15A 20A 30A 30A 40A 40A
Transfer switch rating 30amp for UL & TUV 40amp for UL
Max bypass current 30amp 40amp
Mechanical Specification  Mounting Wall mount
Inverter Dimensions(L*W*H) 382*218*179mm 442*218*179mm 598*218*179mm
Inverter Weight 16KG 17KG 20KG 24KG 35KG 45KG 45KG
Shipping Dimensions(L*W*H) 520*315*300mm 580*315*300mm 740*315*300mm
Shipping Weight 18KG 19KG 22KG 26KG 37KG 47KG 47KG
Display Status LEDs / Status LEDs+LCD
Standard Warranty 1 Year