Safe and Time Saving |
Traditional phase sequence measurement methods must poke the three-phase wire terminal, and connect the three bare alligator clips or test pins of phase sequence meters to the three bare firing lines, while ETCR1000C uses clamp non-contact measurement, without taking off the wire and no need to contact high-voltage bare fire-wire, the test can be made by directly clamping the three-phase insulating sheath by three super-sensitive high-insulated clamps. Conducting measurement on sheathed cable significantly improves the safety of field testing, effectively protect the operator’s personal safety and increase productivity! |
Convenient Operation |
Instrument base plate is provided with magnet, instrument can adsorbed on the metal shell when testing, the operation more convenient. |
Multi-Purpose
|
In addition to phase sequence detection, it also has the functions of live wire examination, simple power detection, fire-wire identification, phase deficiency determination, break location detection, DC line break and line maintenance, equivalent to 3 induction electric pens. |
Dynamic Display
|
LED dynamic display, intuitive and clear |
Sensitive and reliable |
More sensitive ETCR1000C clamp, can even sense the AC voltage signal as low as a few Volts, with a wider range of live electricity. |
Beautiful and scientific |
The three clamps of ETCR1000C are in three colors, Red, Yellow and Green; It is more in line with the distinction of three-phase line, and more scientific and artistic overall appearance. |
Ultra-low Power Consumption |
ETCR1000C has a better power-saving performance with the maximum rated power of 100mVA. |
Ⅱ. Technical Specifications
Functions
|
Phase detection (normal phase, reverse phase and phase deficiency), Live wire examination, Simple Power detection, Breakpoint location and Line maintenance. |
Power Supply |
DC3V AA MN batteries (R6P) ×2 PCS, Continuously working for 200 hours |
AC Voltage Range(V) |
AC0~600V, 40~70Hz (Sine Wave Continuous Input) |
Clamp Wire Size |
Diameter ø1.6-ø16mm
|
LED Display |
[Positive Phase Sequence]
The four phase-sequence lamps blink in order (clockwise).
[Negative Phase Sequence]
The four phase-sequence lamps blink in order (counterclockwise).
[Line-voltage Indication]L1,L2,L3 lamp light up.
[Default Phase]L1/L2/L3 lamp is off.
[Open Circuit]L1/L2/L3 lamp is off.
|
Power On Indication
|
Power on indication light turns on
|
Auto Power off |
After 3 minutes, the meter automatically cut off power supply. |
Meter Dimension |
Width, height, thickness 70mm*75mm*30mm
|
Clamp Lead Length |
0.5m
|
Meter Weight |
180g (with battery)
|
Working Temperature and Humidity |
-10℃~55℃; below 80%rh |
Storage Temperature and Humidity |
-20℃~60℃; below 90%rh |
Maximum Measured Voltage |
AC600V
|
Dielectric Strength |
5.4kVrms
|
Maximum rated Power |
100mVA
|
Safety Provisions |
EN61010-1: 2001, EN61010-031: 2002, Pollution level 2, CAT Ⅲ(600V), Transient over-voltage 6000V |
Accessories |
Meter: 1 Piece; Carrying case; 1 Piece.
|