Electrical Specifications |
|
Model |
1.0KW |
1.5KW |
2.0KW |
3.0KW |
4.0KW |
5.0KW |
6.0KW |
8.0KW |
10.0KW |
12.0KW |
Inverter Output |
Continuous Output Power |
1.0KW |
1.5KW |
2.0KW |
3.0KW |
4.0KW |
5.0KW |
6.0KW |
8.0KW |
10.0KW |
12.0KW |
Surge Rating(20ms) |
3.0KW |
4.5KW |
6.0KW |
9.0KW |
12.0KW |
15.0KW |
18.0KW |
24.0KW |
30.0KW |
36.0KW |
Output Waveform |
Pure Sine wave/Same as input(Bypass Mode) |
Nominal Efficiency |
>88%(Peak) |
Line Mode Efficiency |
>95% |
Power Factor |
0.9-1.0 |
Nominal Output Voltage rms |
100-110-120Vac / 220-230-240Vac |
Output Voltage Regulation |
±10% RMS |
Output Frequency |
50Hz ± 0.3Hz/60Hz ± 0.3Hz |
Short Circuit Protection |
Yes( 1sec after fault ) |
Typical transfer Time |
10ms(Max) |
THD |
< 10% |
DC Input |
Nominal Input Voltage |
12.0Vdc |
( *2 for 24Vdc, *4 for 48Vdc) |
Minimum Start Voltage |
10.0Vdc |
Low Battery Alarm |
10.5Vdc / 11.0Vdc |
Low Battery Trip |
10.0Vdc / 10.5Vdc |
High Voltage Alarm |
16.0Vdc |
Low Battery voltage recover |
15.5Vdc |
Idle Consumption-Search Mode |
< 25 W when Power Saver On |
Charger |
Output Voltage |
Depends on battery type |
Charger Breaker Rating |
10A |
15A |
20A |
20A |
20A |
30A |
30A |
40A |
40A |
40A |
Max Charge Power Rate |
1/3 Rating Power |
Battery Initial Voltage for Start Up |
10-15.7V for 12V( *2 for 24V, *4 for 48V) |
Over Charge Protection Shutdown |
15.7V for 12V (*2 for 24V, *4 for 48V) |
Remote Control |
Yes(Optional) |
Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) |
Nominal Voltage |
110Vac |
120Vac |
220Vac |
230Vac |
230Vac |
Max Input AC Voltage |
150VAC For 120Vac LV Mode; 300VAC For 230Vac HV Mode; |
Nominal Input Frequency |
50Hz or 60Hz (Auto detect) |
Low Freq Trip |
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz |
High Freq Trip |
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz |
Overload protection(SMPS load) |
Circuit breaker |
Output Short circuit protection |
Circuit breaker |
Bypass breaker rating |
10A |
20A |
30A |
40A |
40A |
40A |
50A |
63A |
63A |
Transfer switch rating |
30amp for UL & TUV |
40amp for UL |
80amp for UL |
Bypass without battery connected |
Yes (Optional) |
Max bypass current |
30amp |
40amp |
80amp |
Solar Charger(Optional) |
Rated Voltage |
12Vdc / 24Vdc / 48Vdc |
Solar Input Voltage Range |
15-30Vdc / 30-55Vdc / 55-100Vdc |
Rated Charge Current |
40 ~ 60A |
Rated Output Current |
15A |
Self Consumption |
< 10mA |
Bulk Charge |
14.5V(default) |
( *2 for 24Vdc, *4 for 48Vdc) |
Floating Charge |
13.5V(default) |
Equalization Charge |
14.0V(default) |
Over Charge Disconnection |
14.8V |
Over Charge Recovery |
13.6V |
Over Discharge Disconnection |
10.8 V(default) |
Over Discharge Reconnection |
12.3V |
Temperature Compensation |
-13.2mV/ºC |
Ambient Temperature |
0 ~ 40ºC(Full load) 40 ~ 60ºC(Derating) |
Mechanical Specifications |
Mounting |
Wall Mount |
Inverter Dimensions(L*W*H) |
388*415*200mm |
488*415*200mm |
588*415*200mm |
Inverter Weight(Solar Chg)KG |
21+2.5 |
22+2.5 |
23+2.5 |
27+2.5 |
38+2.5 |
48+2.5 |
49+2.5 |
60+2.5 |
66+2.5 |
70+2.5 |
Shipping Dimensions(L*W*H) |
550*520*310mm |
650*520*310mm |
750*520*310mm |
Shipping Weight(Solar Chg)KG |
23+2.5 |
24+2.5 |
25+2.5 |
29+2.5 |
40+2.5 |
50+2.5 |
51+2.5 |
62+2.5 |
68+2.5 |
72+2.5 |
Display |
Status LEDs / Status LEDs+LCD |
Standard Warranty |
1 Year (Optional) |