Product Main

Specifications

Products Feature:
 Industrial temperature range: -25 ~ +85 Deg.C.
 Power, Signal Input / Output: three-way isolation: 3000VDC
 PWR: 5VDC, 12VDC, 15VDC, 24VDC ± 10% Single Power Supply (when the power supply beyond 5V, there is reverse polarity protection inside.)
 Strain bridge circuit to provide high load capacity of the reference voltage :5V or 10V.
 0-10mV/0-20mV/0- ±10mV/0- ±20mV differential voltage signal input etc., 0-5V/ 0-10V/ 4-20mA international standard output signal.
 Low cost, small size, DIP 24Pin, UL94V-0 flame retardant package PCB soldering or Standard DIN Rail Mouting
 strong anti-electromagnetic interference and EMC, suppression interference of high frequency signal space
 Use of the environment: the surroundings may not have a lot of dust, a strong shock and vibration, as well as a corrosive gas components
 
Products Application:
 Load cell signal transmission,
 Overcome circuit crosstalk, strong electrical interference brought by dispersion acquisition, signal transmission distance
 achieve free connection among the analog signal
 Analog signal ground interference suppression
 Non electrical quantity signal transmission
 Signal transmission distance without distortion
  Overcome the interference caused by the inverter
 
 AZ  -  RV_ - 2mV/V - P_ – O _
 
Reference voltage:             Power Supply:          Output signal          
O1: 0-5V     O2:0-10V
RV1:5V                                  P1:24V                                                            O3:0-2.5V    O4:0-±5V
RV2:10V                                P2:12V                                                           O5:0-±10V   O6:1-5V
RVZ: user-define                 P3:5V                                                            O7:2-10V   O8:0-1mA
                                                     P4:15V                                                           O9:0-10mA   O10:0-20mA
                                                     PZ: user-define                                            O11:4-20mA  OZ: user-define
 
   DIP 24PIN Isolated Pressure-strain bridge signal transducer
Example:
EP1: Reference voltage: 10V 2mv/V  Power supply:24V  Output:4-20mA
Product Model: AZ- RV2-2mv/V-P1-O11
EP2: Reference voltage: 5V  2mv/V  Power supply:5V  Output:0-10
          Product Model: AZ- RV1-2mv/B-P3-O2