Specifications

Contact: pimkin at batterybuilding.com

Place:Unite stations        Color:Yellow      Weight:80.5g     
Specification:18 x 65 mm
 
 

Characters
NO
Items
Specification
Remarks
1
Battery type
LiFePO4
3.2V8.32Wh
2
Brand
K2 Energy
 
3
Nominal capacity
2600mAh
C/5
4
Nominal voltage
3.2V
 
5
Internal resistance
Less than 11 mΩ
C/5
6
Weight
80.5g 
 
7
Continuous discharge current
Less than 10A
 
8
Burst discharge current
26A
 
9
Charge current
2.5A
 
10
Charge cut off voltage
3.65V
 
11
Discharge cut off voltage
2.5V
 
12
Max continuous discharge current
90A
 
13
Max burst discharge current
150A
 
14
Max charge current
5A
 
15
Max charge cut off voltage
4.1V
 
16
Max discharge cut off voltage
2.0V
 



Features:
Low self-discharging rate
High capacity and discharge rate  
Good performance                
Environmental friend

Applications:
Wide application: electric tools, electric bicycle, RC toys, engine start battery and so on.

 

Battery performance:
A:Discharge characteristics:
Discharge capacity/Nominal capacity×100%
 Curves of charging and discharging should be smooth Standard charge at 0.2C5A under 
condition of normal atmospheric pressure and the environmental for 10min and discharge
 at 0.2C5A, 0.5C5A, 1C5A ,2 C5A to 2.5V respectively. Charge/discharge cycle can be conducted for 3 times before
 meeting the Standards (the same below).

B: Normal Storage

 Internal Resistance increase≤20%
Measure initial status and initial capacity. Store for 28 days after standard charge
, the measure final status and residual capacity at 0.5C5A to 2.5V;After charge/discharge
 (0.5C5A/0.5C5A) cycle can be conducted for 3 times, recoverable capacity will be tested at 0.5C5A
C:Cycle Life
Discharge capacity≥Nominal Capacity*80%
Measure initial status and initial capacity, then conduct 1C5A/1C5A cycle for 1000 times. The discharge capacity shall be measured after 1000 cycle.
D: High-low Temperature Discharge
0.2C5A Discharge time Stores 3 month-long the batteries ≥4.5h; Stores 6 month-long the batteries ≥4.25h; Stores 12 month-long the batteries ≥4h.  Measure initial capacity and initial status. Battery charge after 3.35V .measure initial capacity. The distinction room temperature stores 3 months, 6 months, 12 months later, measure battery's final condition,Then circulates 3 time record battery's discharge time by 0.5C/0.5C. 
 

 






 

  •