Product Main

Specifications

HD Series Structure Chart
  • Modular assembling: modular structure makes it possible to install it very easily, and it's just half size of traditional one.
  • Less system pressure loss: saving energy at the maximum limit.
  • Long-lasting and high performance desiccant: to ensure a stable dewpoint and an excellent dry performance.
  • Desiccant pressure springs: protect the desiccant from moving or smashing during the circular switchover.
  • Installation: with unique parallel installation, just N+1 units can reach 100% backup machine to reduce purchase cost.
 
 
Technical Specifications & Selection Table
 
Maximum Inlet Temp. 50°C
Minimum Inlet Temp. 2°C
Working Ambient Temp. 2~45°C
Maximum Working Pressure 10 bar g
Minimum Working Pressure 4 bar g
Noise ≤75dB
Power Supply
230V AC 50/60Hz
110V AC 50/60Hz
Power 50W
PDP -40°C, -70°C
Air Consumption ≤15%
Pressure Drop 0.14 bar g
 
 
 
Model
Flow Range
Nm³/min
@7bar,35°C
Dimensions (mm) Pipe Size Weight (Kg)
-40°C -70°C A B C D E
GHD0390 3.9 2.73 320 1720 600 260 234 G2" 200