Product Main

Specifications

Product Type: FVN/FVNP Nylon sheath cable
1.Rated voltage: 300/500V,  450/750V 
2. Operating temperature: -60 ~ +105 ℃
3. Conductor: stranded tinned copper 
4. Insulation: polyvinyl chloride (PVC) 
5. Jacket: Nylon (NL) 
6. Color: red / yellow / blue / white / black / green / brown etc. 
7.Product capability: a wear-resistant, waterproof,cold,oil-resistant mixture of gasoline, not combustion, not aging, environmental protection, in the 98 percent relative humidity in the environment can be used normally. 

Application:
Widely used in aircraft low-voltage lines and highways to install monitoring equipment, with lines and highways electricity flu coil-only lanes(electronic police line, in line with coil flu) also used for lighting cables. Particularly applicable for use in the cold.Delivery length short line segment allowing not being smaller than 10 meters, that whose quantity can not exceed general quantity of delivery 10%. 


Cross Section mm2 Conductor
 structure
Insulation thickness 
mm
Jacket thickness 
mm 
At  Maximum conductor resistance Ω /km  
Root 
number
/single diameter
0.3 16/0.15 0.35 0.12 71.2
0.35 7/0.26 0.35 0.12 50.8
19/0.16 0.35 0.12 50.8
0.5 7/0.30 0.35 0.12 40.1
19/0.20 0.35 0.12 40.1
28/0.15 0.35 0.12 40.1
0.75 7/0.37 0.35 0.12 26.7
19/0.23 0.35 0.12 26.7
24/0.20 0.35 0.12 26.7
42/0.15 0.35 0.12 26.7
1 7/0.43 0.35 0.14 20
19/0.26 0.35 0.14 20
32/0.20 0.35 0.14 20