Product Main

Specifications

AE411 Laser anti-collision device
Specially designed for the hositing machinery( travelling crane, bright crane, rail crane, gantary crane, etc).
Specifications

DescriptionParameter
Specifications for displayer
VoltageAC85-265V(designated)
Frequency50Hz~60Hz
Alarm volume0dB-80dB
Response time0.1S
Output contactNormally closed contact
Wattage<10W
Output contact load(resistance) mainframe— 12A 125VAC
7A 250VAC
7A 30VDC
WeightAE411A: 0.8Kg;
AE411B: 0.3Kg;
AE411C: 0.8Kg;
Ambient temperature-30C ~ +70C
IP protectionAE411A: IP65; AE401C: Indoor
Humidity10% ~ 95% (no condensing)
InstallationBolt fixed
Specifications for the sensor

Detection distance200mm20m
Spot diameterΦ =200mm(20m)
VoltageDC18-30V
Switched outputPNP
Input current Imax100mA
Current load≤ 250mA
Trigging time50/s
IP protectionIP65
VDE protectionII level
Ambient temperature-15C ~ +55C
Guard circuit*A, B, D
*A=Uv joint against anti-joint
B=output end anti-overcurrent and short-circuitproof
D= output end anti-overcurrent and short-circuitproof
Manjor functions and features

Adopt impoted laser sensor.
Detection distance: 200mm...20m.
Each sensor on the left and rigth for checking two directions. Two-way normally closed node output each side.
Voice alarm, continuous and three-times voice mode can be switched, adjustable volume.
High integration design, flexible installation, reliable quality.
Self-check function, pause function.
System block diagrams

Optical system:
1. A displayer, A sensor, A reflector, this system is single controlled;
2. A display, 2 Sensors, 2 reflectors, This system is double controlled;

AE411C Adjustment:
1, Press shelf-check button, red alarm light are burning, relay has the output(pic. 4)
2, AE411A transmit the signal to the displyer, the homologous red alarm light burns. Press the"pause" button, the voice stops.
3, Press"Volume +" or"Volume " to adjust the volume.
4, Press"Mode"button, voice mode can be switched between " Continuous" and "Three times".

AE411A adjustment: AE411A set-up panel as pic. 5, the set-up steps as follow:
1, Offer DC 18-30V to AE411A. Point AE411A correctly to the reflector.
2, Rotate"Align"to Q1, Press"Teach", Indicator light Flashes. When the light are steady burning, the distance S1 is setted successfully.
3, Set S2(Q2) per the same above procedure.
4, Rotate"Align"to"Run", all settings are done.
5, When the distance between AE411A and reflector is not larger than S1, Q1 outputs. When the distance between.
AE411A and reflector is not larger than S2, Q2 outputs.
Notice:

AE411C only can be fixed indoor.
Check the voltage of power and AE411C whether they are corresponding.
Connect the cables according to the wiring diagram, Do not make the short circuit.
The temperature rise is normal when use the controller.
Keep the lentiform of reflector and sensor clear. Pollution will affect the reliablility. What's worse, the product will be scrap. Please clear the products every 6 months periodically.
Please read the instruction carefully. Do not open the case privately.