Ⅰ. Introduction
Safe and Time Saving
Traditional phase sequence measurement methods must poke the three-phase wire terminal, and connect the three bare alligator clips or test pins of phase sequence meters to the three bare firing lines, while ETCR1000D Large Caliber Non-contact Phase Sequence Detector uses clamp non-contact measurement, without taking off the wire and no need to contact high-voltage bare fire-wire, the test can be made by directly clamping the three-phase insulating sheath by three super-sensitive high-insulated clamps. Conducting measurement on sheathed cable significantly improves the safety of field testing, effectively protect the operator’s personal safety and increase productivity!
Convenient Operation
Instrument base plate is provided with magnet, instrument can adsorbed on the metal shell when testing, the operation more convenient.
Multi-Purpose
In addition to phase sequence detection, it also has the functions of live wire examination, simple power detection, fire-wire identification, phase deficiency determination, break location detection, DC line break and line maintenance, equivalent to 3 induction electric pens. 
Dynamic Display
LED dynamic display, intuitive and clear
Sensitive and reliable
More sensitive ETCR1000D clamp, can even sense the AC voltage signal as low as a few Volts, with a wider range of live electricity.
Beautiful and scientific
The three clamps of ETCR1000D are in three colors, Red, Yellow and Green; It is more in line with the distinction of three-phase line, and more scientific and artistic overall appearance.
Ultra-low Power Consumption
ETCR1000D has a better power-saving performance with the maximum rated power of 100mVA.
 
Ⅱ. Technical Specifications
Functions
Phase detection (normal phase, reverse phase and phase deficiency), Live wire examination, Simple Power detection, Breakpoint location and Line maintenance.  
Power Supply
DC3V AA MN batteries (R6P) ×2 PCS, Continuously working for 200 hours
AC Voltage Range(V)
AC0~600V, 40~70Hz (Sine Wave Continuous Input)
Clamp Wire Size
Diameter ø10-ø40mm
LED Display
[Positive Phase Sequence]
The four phase-sequence lamps blink in order (clockwise).
[Negative Phase Sequence]
The four phase-sequence lamps blink in order (counterclockwise).
[Line-voltage Indication]L1, L2, L3  lamp light up.
[Default Phase]L1/L2/L3  lamp is off.
[Open Circuit]L1/L2/L3  lamp is off.
Power On Indication
Power On indication light turns on
Auto Power off
After 3 minutes, the meter automatically cut off power supply.
Meter Dimension
Width, height, thickness 70mm*75mm*30mm
Clamp Lead Length
0.5m
Meter Weight
180g (with battery)
Working Temperature and Humidity
-10℃~55℃; below 80%rh
Storage Temperature and Humidity
-20℃~60℃; below 90%rh
Maximum Measured Voltage
AC600V
Dielectric Strength
5.4kVrms
Maximum rated Power
100mVA
Safety Provisions
EN61010-1: 2001, EN61010-031: 2002, Pollution level 2, CAT Ⅲ(600V), Transient over-voltage 6000V
Accessories
Meter: 1 Piece; Carrying case; 1 Piece.