Multi-fiber Tight-buffered Armored Fiber Optic Cable?
APPLICATIONS?
*Apply to all types of optical connectors
*Apply to pigtails and patch cords
*Apply to connectors in optical communication equipment rooms, distribution frames and FTTX
*Apply to optical appliances connection
*Apply to indoor horizontal or vertical cabling, multi-medium connection, LAN
*Apply to connections of long distance, outdoor, building cabling, combination cabling of fiber optic and electronic.
*Apply to high density cabling?
*Apply to pigtails and patch cords
*Apply to connectors in optical communication equipment rooms, distribution frames and FTTX
*Apply to optical appliances connection
*Apply to indoor horizontal or vertical cabling, multi-medium connection, LAN
*Apply to connections of long distance, outdoor, building cabling, combination cabling of fiber optic and electronic.
*Apply to high density cabling?
FEATURES?
*Good mechanical and environmental characteristics
*Soft, flexible, Stable, easy to splice
*Flame retardant characteristics meet the requirements of relevant standards
*Improve existing function based on customers’ various requirements?
*Soft, flexible, Stable, easy to splice
*Flame retardant characteristics meet the requirements of relevant standards
*Improve existing function based on customers’ various requirements?
DETAILS:
*Fiber Type: Single-mode fiber G652, G657, G655, Multimode fiber 50/125,62.5/125, OM3,
*Jacket Material: PVC, LSZH, TPU, ETFE etc.
*Jacket Color: G652-Blue, G657-Gray, G655-Green, Multimode Fiber-Orange(or Gray),
*Stainless Steel Tube: SUS304, SUS204, or other contracted materials requests
*Other Requirements: other contracted special requests?
*Jacket Material: PVC, LSZH, TPU, ETFE etc.
*Jacket Color: G652-Blue, G657-Gray, G655-Green, Multimode Fiber-Orange(or Gray),
*Stainless Steel Tube: SUS304, SUS204, or other contracted materials requests
*Other Requirements: other contracted special requests?
CABLE PARAMETERS
STRUCTURE SIZE (TABLE ONE)
|
Cable Count |
ITEM | CABLE OD.mm(a) | S.S.T.OD.mm(b) | T.B.O.F.OD.mm(C) |
| 4 | 4.5MM-4S | Φ4.5±0.2 | Φ2.5±0.02 | Φ0.6 |
| 6 | 5MM-6S | Φ5.0±0.2 | Φ3.0±0.03 | Φ0.6 |
| 8 | 5.5MM-8S | Φ5.5±0.2 | Φ3.2±0.05 | Φ0.6 |
| 10 | 6.0MM -10S | Φ6.0±0.25 | Φ3.8±0.05 | Φ0.6 |
| 12 | 7.5MM-12S | Φ7.0±0.25 | Φ4.2±0.05 | Φ0.6 |
| 24 | 5MM-24S | Φ8.5±0.3 | Φ5.0±0.05 | Φ0.6 |
MECHANICAL PROPERTIES(TABLE TWO)
| ITEM |
CABLE OD. mm(a) |
CABLE WEIGHT | BEND RADIUS* |
L.P. N/100mm |
|||
| S.T. | L.T. | Dyn. | Sta | ||||
| 4.5MM-4S | Φ4.5±0.2 | 27.5 | 800 | 400 | 70 | 35 | 3000 |
| 5MM-6S | Φ5.0±0.2 | 32.5 | 1000 | 500 | 100 | 50 | 3000 |
| 5.5MM-8S | Φ5.5±0.2 | 36.0 | 1000 | 500 | 100 | 50 | 3000 |
| 6.0MM -10S | Φ6.0±0.25 | 42.0 | 1000 | 500 | 120 | 60 | 3000 |
| 7.5MM-12S | Φ7.0±0.25 | 50.0 | 1200 | 600 | 150 | 75 | 3000 |
| 5MM-24S | Φ8.5±0.3 | 61.0 | 1500 | 750 | 170 | 85 | 3000 |
OD. = Outside Diameter S.T.=Short Term L.T.=Long Term Dyn. = Dynamic Sta. = Static
L.P. = Lateral Pressure S.S.T.OD.= Stainless Steel Tube Outside Diameter
T.B.F.OD. = Tight-Buffered Outside Diameter
*All the values in the table two are for reference only
*The bending radius of G657 series fiber will be less than 15mm
L.P. = Lateral Pressure S.S.T.OD.= Stainless Steel Tube Outside Diameter
T.B.F.OD. = Tight-Buffered Outside Diameter
*All the values in the table two are for reference only
*The bending radius of G657 series fiber will be less than 15mm