Product Main

Specifications

Gasboard—5020 emission gas analyzer can be used for measurement of the concentration of automobile emission gas CO, CO2, HC, O2 and NO (optional). It is based on the pulsable infrared source and single source two beams non-dispersion infrared (NDIR) method, this analyzer is designed with portable and smaller physical dimensions.

Measurement range:
CO:0-10%, CO2:0-20 % ,HC:0-9999ppm, O2:0-25% , NO:0-5000ppm( optional)
Error:
HC:±12ppm or±5% (relative)     
CO:±0.06% or±5% (relative)     
CO2: ±0.5% or±5% (relative)     
O2: ±0.1%or±5% (relative)     
NO:±25ppm or±4% (relative)
Resolution:HC:1 ppm CO:0.01 % CO2:0.01 % O2:0.01 % NO:1 ppm
Response time: Less than10s(NDIR)
Warming up:10min
Power: AC220V±10%,50HZ±1HZ
Weight:6.5kg
Dimension:266mm(width)×360mm(depth)×183mm(height)
 
Front & Back panels 
                                     
Standard accessories: Sampling probe, sampling pipe, filter elements, RS232 cable
   
Optional accessories: Oil temperature sensor, Engine RPM sensor based on cigar lighter Gasboard-8010, RPM sensor based on vibration Gaboard-8110