Product Main

Specifications

Specification:
Cat.No Conductors
Main mm2
Branch mm2
Piercing Depth
Rating Current
Weight
Package
Exterior Size:
JMA2-150
50-150
4-35(50)
>or=3 mm
200 A
188 g
100
51× 60×87mm
 
Detailed Product Description
1. CE, ISO9001,
2. Waterproof, fire resistant, corrosion-resistant, anti-climate change, anti-UV
3. with good quality and low price
4. Test voltage 4 kV/50 Hz/1min in water.
5. used with insulated Al or Cu conductors. Fully sealing rubber provides safe live line working.
6. Both main and branch conductor insulations are pierced by a single bolt action.
7. The shear head bolt and end cap are insulated.
8. Constant puncture fastening torque nut is installed simpler, safe, and fast.
9. Extension puncture site and contact with senior waterproof cover functions (IP27), the water pressure of 6 KV
10. Extension Cover may as required under extreme left or right side.
 
Application
1. Low voltage overhead lines
2. Building Distribution System
3. Low-voltage lines into households
4. Streetlights distribution system and so insulated cable connecting branch