Product Main

Specifications

60W Single Output Switching Power Supply S-60
 
1) Features:
  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • 100% full load burn-in test
  • Fixed switching frequency at 77KHz
  • 1  year warranty 
 
2) 60W Single Output Switching Power Supply S-60 Specification:
MODEL S-60-5 S-60-12 S-60-15 S-60-24
DC VOLTAGE 5V 12V 15V 24V
RATED CURRENT 12A 5A 4A 2.5A
CURRENT RANGE 0 ~ 12A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A
RATED POWER 60W 60W 60W 60W
RIPPLE & NOISE (max. ) Note. 2 120mVp-p 120mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V
VOLTAGE TOLERANCE Note. 3 ± 2.0% ± 1.0% ± 1.0% ± 1.0%
LINE REGULATION ± 0.5% ± 0.5% ± 0.5% ± 0.5%
LOAD REGULATION ± 1.0% ± 0.5% ± 0.5% ± 0.5%
SETUP, RISE TIME 300ms, 50ms, /230VAC          800ms, 50ms/115VAC at full load
HOLD TIME(Typ. ) 90ms/230VAC          12ms/115VAC at full load   
VOLTAGE RANGE 85 ~ 264VAC        120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ. ) 73% 76% 77% 79%
AC CURRENT 2A/115VAC            1A/230VAC
INRUSH CURRENT (max. ) COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT < 3.5mA / 240VAC
OVERLOAD 105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE  5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
WORKING TEMP. -10 ~ +60º C (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85º C , 10 ~ 95% RH
TEMP. COEFFICIENT ± 0.03%/º C (0 ~ 50º C)
VIBRATION 10 ~ 500Hz, 2G 10min. /1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS Design refer to UL1012, UL1950, TUV EN60950 
WITHSTAND VOLTAGE I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance to EN61000-3-2, -3
EMS IMMUNITY Compliance to EN61000-4-2,3,4,5;6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF 316.2K hrs min. MIL-HDBK-217F (25º C)
DIMENSION 159*97*38mm (L*W*H)
PACKING 0.463Kg; 30pcs/15.56Kg/0.0250CBM
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25° C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.