AC Outdoor High Voltage V Model Disconnector
Description & Application
SID1-40.5 outdoor high voltage disconnector is a three-phase AC outdoor high voltage electric accessory for double-column, horizontal isolating distance and center open-type. It is used to switch high voltage line in the non-load condition of rated voltage 40.5kV, 50/60Hz electric system. It will form a safe electric disconnecting when the workman examine and repair the high voltage busbar, circuit breaker and the other high-voltage electric equipment.
Technical Parameter & Detail Show
Technical Parameter
Technical Parameter
| Item | Data | |
| Rated Voltage(kV) | 40.5 | |
| Rated Current(A) | 630,125,016,002,000 | |
| Rated Frequency(Hz) | 50Hz/60Hz | |
| Rated Lightning Impulse Withstand Voltage(kV) | 185(Phase to Earth) | |
| 170(The data of neutral ground system) | ||
| 215(Across Isolating Distance) | ||
| 200(The data of neutral ground system) | ||
| Rated Power Frequency Withstand Voltage(kV) | 95(Phase to Earth) | |
| 80(The data of neutral ground system and wet test) | ||
| 118(Across Isolating Distance) | ||
| 103(The data of neutral ground system and wet test) | ||
| Auxiliary and Control Circuit Power Frequency Withstand Voltage (kV) | 2 | |
| Rated Short-Time Withstand Current (kA/S) | 20kA, 25kA, 31.5kA, 40kA, 50kA, 63kA/4S | |
| Rated Peak Withstand Current | 50, 63, 80, 100, 125, 160 | |
| Rated Mechanical Load Data of Wire Holder (N) |
Across Horizontal:500 Length Wise Horizontal:750 Vertical:750 |
|
| Mechanical Life(Times) | 3000times | |
Material
Main conductive & earthing conductive
The main conductive & earthing conductive of disconnector are made of casting alloy which of high strength and good performance of conductive & anti-corrosion, it decreases the influence of skin-effect to make current distribution evenly and extend heat dissipation to maximization, it is able to support more working current.
Main contact & contact finger
The main contact and contact finger are made of copper plated silver, while the contact finger spring is made of stainless steel. The contact/contact finger opens/closes by sliding, with the function of self-cleaning and self-strict. It can ensure the optimum of contact/contact finger when short circuit current occurs.
Application Conditions
1 Ambient Temperature: -40℃~+55℃
2 Elevation: ≦2,000m
3 Seismic Intensity: ≦8
4 Maximum Wind Speed: 35m/S
Installation Methods
SID1-40.5 high voltage disconnector is used “V” shape 90°rotation to twirl, various installations are acceptable. Such as horizontal mounted, vertical mounted , reverse mounted and 25° inclination mounted. It can be suited for multi-azimuth way of outlet & inlet line on the power station.
Standards
GB1985-2004
GB/T11022-1999
GB50150-2006
DL/T 486-2000
DL/T593-2006
IEC 62271-102
Service
Shipping
1 Sea Way
2 Air Way
3 Express
Payment
1 PayPal
2 West Union
3 Wire Transfer
4 T/T