1000w pure sine wave power inverter generator
Inverter generator key features:
To inverter:
- High overload ability up to 300% rated power (20 sec)
- Low voltage trip selectable (9.5V/10V or 10V/10.5V) extracting max power from various batteries with different protection
- Low quiescent current, power saver mode to reduce power consumption to 10W (3 sec sensing cycle)/3W (30s sensing cycle)
- DC13V battery recover point, dedicated for solar systems
Technical specifications:
|
General specifications:
|
||||||
|
Input wave form:
|
Sine wave(Utility or generator)
|
|||||
|
Nominal voltage:
|
120VAC
|
230VAC
|
||||
|
Low voltage trip:
|
80V/90V+/-4%
|
184V/154V+/4%-
|
||||
|
Low voltage re engage:
|
90V/100V+/-4%
|
196V/164+/-4%
|
||||
|
High voltage trip:
|
140V+/-4%
|
253V+/-4%
|
||||
|
High voltage re engage:
|
135V+/-4%
|
243V+/-4%
|
||||
|
Max input AC voltage:
|
150VAC
|
270VAC
|
||||
|
Nominal input frequency:
|
50Hz or 60Hz(Auto detect)
|
|||||
|
Low frequency trip:
|
47Hz for 50Hz, 57Hz for 60Hz
|
|||||
|
High frequency trip:
|
55Hz for 50Hz, 65Hz for 60Hz
|
|||||
|
Output wave form:
|
(Bypass mode) same as input
|
|||||
|
Overload protection:
|
Circuit breaker
|
|||||
|
Short circuit protection:
|
Circuit breaker
|
|||||
|
Transfer switch rating:
|
30 amp or 40 amp
|
|||||
|
Efficiency on line transfer mode:
|
95%+
|
|||||
|
Line transfer time:
|
10 ms typical
|
|||||
|
Bypass without battery connected:
|
Yes
|
|||||
|
Max bypass current:
|
30 amp or 40 amp
|
|||||
|
Bypass over load current:
|
35 amp or 45 amp: alarm
|
|||||
|
Inverter specification/output
|
||||||
|
Output wave form:
|
Pure sine wave
|
|||||
|
Output continuous power watts:
|
1000
|
2000
|
3000
|
4000
|
5000
|
6000
|
|
Output continuous power VA:
|
1000
|
2000
|
3000
|
4000
|
5000
|
6000
|
|
Power factor:
|
0.9-1.0
|
|||||
|
Nominal output voltage rms:
|
120/230VAC
|
|||||
|
Output voltage regulation:
|
+-/10% rms
|
|||||
|
Output frequency:
|
50Hz+/-0.3Hz or 60Hz+/-0.3Hz
|
|||||
|
Nominal efficiency:
|
>88%
|
|||||
|
Surge ratings:
|
3000
|
6000
|
9000
|
12000
|
15000
|
18000
|
|
Short circuit protection:
|
Yes, fault after 1 sec
|
|||||
|
THD
|
<10%
|
|||||
|
Inverter specification/input:
|
||||||
|
Nominal input voltage:
|
12.0V
|
24.0V
|
48.0V
|
|||
|
Minimum start voltage:
|
10.0V
|
20.0V
|
40.0V
|
|||
|
Low battery alarm:
|
10.5V/11.0V
|
21V/22.0V
|
42.0/44.0V
|
|||
|
Low battery trip:
|
10.0V/10.5V
|
20.0V/21V
|
40.0V/42V
|
|||
|
High voltage alarm:
|
16.0V
|
32.0V
|
64.0V
|
|||
|
Low battery voltage recover
|
15.5V
|
31.0V
|
62.0V
|
|||
|
Power saver:
|
Below 25 watts when enabled
|
|||||
|
Power saver:
|
Same switched on/off on remote
|
|||||
|
Charger mode specifications:
|
||||||
|
Input voltage range:
|
90-135VAC
|
194-243VAC/164-243VAC(W)
|
||||
|
Output voltage:
|
Dependent on battery type
|
|||||
|
Max charger current:
|
35A/70A (Charger current controller)
|
|||||
|
Battery initial voltage for start up:
|
10-15.7V for 12V(*2 for 24V; *4 for 48V)
|
|||||
|
Over charger protection shutdown:
|
15.7V for 12V(*2 for 24V; *4 for 48V)
|
|||||
|
Charger curves (4 stage constant current) battery types
|
||||||
|
4 steps digital controlled progressive charge
|
||||||
|
Battery type:
|
Fast V
|
Float V(*2 for 24V; *4 for 48V)
|
||||
|
GEL U.S.A.
|
14.0
|
13.7
|
||||
|
A.G.M. 1
|
14.1
|
13.4
|
||||
|
A.G.M. 2
|
14.6
|
13.7
|
||||
|
Sealed lead acid
|
14.4
|
13.6
|
||||
|
GEL Euro
|
14.4
|
13.8
|
||||
|
Open lead acid
|
14.8
|
13.3
|
||||
|
Calcium
|
15.1
|
13.6
|
||||
|
De-sulphation
|
15.5 for 4 hrs
|
|||||
|
Remote control/RS232/USB
|
Yes, optional
|
|||||
|
Mounting
|
Wall mount
|
|||||
|
Size: in mm
|
1000 model: 520*315*300 mm3
|
|||||
|
|
2000/3000 model: 580*315*300 mm3
|
|||||
|
4000/5000/6000 model: 740*315*300 mm3
|
||||||
|
Gross weight:
|
1000
|
2000
|
3000
|
4000
|
5000
|
6000
|
|
20Kg
|
22Kg
|
26Kg
|
37Kg
|
47Kg
|
47Kg
|
|

