Outdoor AC High Voltage Vacuum Circuit Breaker
Description & Application
The product is designed according to the most advanced international ideas: the APG coating silicone rubber insulation technology of epoxy resin is used on the pole of vacuum arc-extinguishing chamber. The main application is to protect and control the distribution network of substation, mine industries, town and country and so on.
Technical Parameter & Detail Show
Technical Parameter
Item
|
Unit
|
Data
|
||
Rated Voltage
|
kV
|
12
|
24
|
|
Rated Insulation Level
|
1 min Power Frequency Withstand Voltage(Dry/Wet)
|
kV
|
42(Across isolating distance 49)/34
|
65(Across isolating distance 79)/52
|
Lightning Impulse Withstand Voltage (Peak)
|
75(Across isolating distance 85)
|
125(Across isolating distance 145)
|
||
Rated Current
|
A
|
630
|
1250/630
|
|
Rated Short-Circuit Breaking Current (Peak)
|
kA
|
20
|
25
|
|
Rated Short-Circuit Making Current (Peak)
|
50
|
60
|
||
4s Rated Short-Time Withstand Current
|
20
|
25
|
||
Rated Peak Withstand Current
|
50
|
60
|
||
Rated Operating Sequence
|
|
Off-0.3s-On/Off-180s-On/Off
|
Off-0.3s-On/Off-180s-On/Off
|
|
Breaking Times of Rated Short-Circuit Breaking Current
|
times
|
30
|
30
|
|
Times of Mechanical Life
|
10000
|
10000
|
||
Rated Operating Voltage
|
V
|
(DC, AC)220
|
(DC, AC)220
|
|
Operating Mode
|
|
Spring Operation (Electric/Manual)
|
Spring Operation (Electric/Manual)
|
|
Outline Dimension
|
mm
|
945×420×745
|
1200×600×950
|
|
Weight
|
kg
|
60
|
150
|
Notes: When using the product at the place where is above 1000m of sea level, relative amendment should be made on insulation withstand voltage which according to standard GB/T 11022.
Material
The Configuration of Current Transformer
External current transformer works as protection, with the transformation ratio 50/5600/5 and the standard configuration is 2pcs. The maximum quantity is 6pcs (one group is for measurement, the other group is for protection). Once the requirement of measuring winding precision is above level 0.5, the transformation ratio is 200/5,300/5,400/5,600/5.
Operating Power Supply
The operating supply is from the AC/DC low-voltage 220V (110V) provided by users or from the secondary voltage of AC 220V (110V) output by the voltage transformer (external) connected to the 10kV overhead line. For the purpose of convenient installation, the outdoor type voltage transformer with fuse protector is recommended.
Application Conditions
1 Ambient Temperature: -45℃~+40℃
2 Range of Daily Temperature: ≤25℃
3 Wind Speed: ≤35m/s
4 Elevation: ≤1000m
5 Seismic Intensity: ≤8 degrees
6 Ambient Humidity: Monthly value of relative humidity ≤90%, daily average value of relative humidity ≤95%
7 Thickness of Ice: ≤20mm
8 Application Site: No danger of inflammability and explosion, chemical corrosion or violent vibration.
Standards
IEC 56
GB 1984
GB/T11022
DL/T 615
DL/T 403