Features
* 100 ~ 240VAC wide input voltage
* Small volume, light weight, high efficiency
* Protection feature: short circuit, overload protection
* Nature air cooling
* 100% full load burn-in test
* Quality assurance for 1 year
* Dimension: 85*60*33mm
* 100 ~ 240VAC wide input voltage
* Small volume, light weight, high efficiency
* Protection feature: short circuit, overload protection
* Nature air cooling
* 100% full load burn-in test
* Quality assurance for 1 year
* Dimension: 85*60*33mm
| Model | WQ-101-12 |
WQ-101-24
|
|
| Output | AC Output Voltage | 12V | 24V |
| Output Capacitance | ±1% | ±1% | |
| Rated Output Current | 2A | 1A | |
| Range of Output Current | 0~4A | 0~2A | |
| Output Power | 24W | 24W | |
| Ripple and Noise | 100mVp-p | 180mVp-p | |
|
Adjustable Range Of AC Voltage |
±5% | ±5% | |
| Start, Rising, keep time | 200ms, 100ms, 30ms/230VAC. | ||
| Input | Range Of Input Current | 100~240VAC 47~63Hz | |
| Dc Input Current | Max 0.42A | ||
| Efficiency | ≥80% | ≥85% | |
| Impulse Current | 20A/230V(Cold Start Current) | ||
| Leakage Current | <3.5mA/240VAC | ||
| Protection feature | Over protection |
The 115%~135% of rated output power launch overload protection. |
|
| Protected way: Hiccup mode, Automatic recovery after removal of abnormal load conditions | |||
| Over Voltage Protection | Cut Off the Output, Automatic recovery. | ||
|
Over Temperature Protection |
≥105℃ Cut Off the Output, Automatic recovery. | ||
| Environment | Work Temperature , Humidity | -10℃~+60℃; 20%~90%RH | |
| Safety | Resistance To Pressure |
The input and output: 1.5KVAC Input And: 1.5KVAC Output And: 0.5KVAC |
|
| Insulation Resistance | The input and output: Input And, Output And: 100M Ohms/500VDC | ||
| Others | Weight/Package | 0.137kg/100PCS/13.7kg/15.1kg Dimensions Of the outbox: 40*34*20cm | |
Comment:
1. All parameters which are not pionted in particular, are tested under 230 vac voltage input, rated load and 25℃.
2. Ripple and noise voltage are tested in 20 MHZ bandwidth oscilloscope with 12 inches twisted-pair cable end with extra 0.1u and 47u capacitance.
3. Tolerance is the total sum of voltage setting error, voltage regulation and current regulation .