Outdoor AC High Voltage Vacuum Load Break Switch
Description & Application
PVS1-12 vacuum load break switch is suitable for 50Hz three-phase distribution system proving the performance of on-off current and on-off short circuit current. It is suitable for being protection and control in substation and power distribution system of industrial & mining enterprises, but more applicable for the place where the power network has been frequently used.
Technical Parameter & Detail Show
Technical Parameter
Item | Unit | Data | |
Rated Voltage | kV | 12 | |
Rated Current | A | 630 | |
Rated Short-Time Withstand Current(4s) | kA | 12.5, 16, 20 | |
Rated Short-Circuit Making Current (Peak) | 31.5, 40, 50 | ||
Rated Frequency | Hz | 50 | |
Rated Voltage | V | AC220(80%~110%) | |
Rated Insulation Level | 1 min Power Frequency Withstand Voltage (Phase to Earth, Phase to Phase/Across the Isolating Distance) | kV | 42/49 |
Lightning Impulse Withstand Voltage (Peak) (Phase to Earth, Phase to Phase/Across the Isolating Distance) | 75/85 | ||
Secondary to Earth | 2 | ||
Rated Gauge Pressure of SF6 Gas | Mpa | 0 Gauge Pressure, Intensity>93% | |
Manual Force of Operating Handle | N | 100~400 | |
The Main Loop Resistance (cable/pipe type) | μΩ | ≤455/≤150 | |
Switch-On Time | ms | 120~180(220V), <400(184V) | |
Attracting Current (Peak) | A | <17 | |
Bounce Time of Contact Closing Switch | ms | <6 | |
Holding Current | A | 0.35~0.45 | |
Minimum Switch on Voltage | V | 120~160 | |
Switch-Off Time | s | <1.5 | |
Different Time of Contact Off | ms | <30 | |
Minimum Maintaining Pull-In Voltage | V | 65~85 | |
Switch On-Off Time Difference Between Isolating Distance and Vacuum Arc Chamber | ms | >10 | |
Power Loss | W | >10 | |
Breaking Current Open Circuit Test | A | >1400 | |
Tightness Test (for leakage) | Mpa | 0.02 Gauge Pressure,No Leakage | |
Distance of Vacuum Arcing Chamber Contact | mm | 7~9 | |
Over Travel of Vacuum Arcing Chamber Contact | mm | 3~3.5 | |
Isolating Distance | mm | 25~30 | |
Isolating Distance Over-Travel | mm | 6~13 | |
Operating Method | Electric/Manual | ||
Net Weight | kg | 185 |
The load break switch adopts vacuum arc extinction and SF6 gas as insulator medium with excellent performance of tightness and no-maintenance. The isolation knife of the switch makes parallel connection with three-pole vacuum arc-extinguishing chamber, with good on-off operating simultaneity; and when it is off, there is a reliable isolating breaking point, with the same function to disconnector.
Application Conditions
2 Ambient Temperature: -40℃~+40℃, Daily Temperature Difference: daily temperature change ≤25℃
4 Application Site: No danger of inflammable, explosion, strong chemical corrosion (such as acid, alkali or fume etc.) and violent vibration.
GB 3804
GB/T 11022
GB 311.1
GB 3309
GB 4208
DL/T 593
DL/T 884
GB 8905
GB 50150