Product Main

Specifications

Outdoor AC Cable Branch Box
 
Description & Application
 
DMC series cable junction cabinet is widely used in AC power transmission and distribution system, to distribution of electrical energy. The connection mode is simple, convenient, besides all the insulation, seal, corrosion resistance, easy extension, free maintenance etc.
 
Technical Parameter
 
Item
Data
Rated Voltage
11kV
Max. Working Voltage
15kV
Rated Current
630A
Rated Frequency
50Hz
Rated Thermal Stability Current
20kA/4s
Rated Dynamic Current(Peak)
50kA
Rated Breaking Current
630A
Rated On-off Current
50kA
Rated Cable Charging Breaking Current
30A
Rated Power Frequency Withstand Voltage
(Phase to Earth/Across Isolating Distance)
42kV/48kV
Rated Lightning Impulse Withstand Voltage
(Phase to Earth/Across Isolating Distance)
95kV/125kV
Joint Resistance
≤40μΩ
Working Temperature of Conductive Parts
≤95°C
Partial Discharging
≤10pC/13kV
Humidity Test
11kV/100h
Apply to Cable Type
XLPE
Apply to Cable Cross-Section
20-400mm2
Ambient Temperature
-40~+50°C
Elevation
≤3000m
630A Operation Times(Mechanical Life)
>100 times
Mechanical Operation of Switch On-Off(Load Break Switch/Disconnector/Earthing Switch)
5000/2000
 
Application Conditions
 
Item
Data
Ambient Temperature
Max. Temperature
40°C
Max. Average Daily Temperature
35°C
Min. Temperature
-40°C
Humidity
Max. Average Humidity
 
24hours
≤95%
1month
≤90%
SF6 Gas Pressure
1.4Bar with 20°C (Absolute Pressure)
Yearly Leakage Ratio
≤0.1%/Year
Cable Sleeve Standard
DIN47636T1
Protection Level
SF6 Gas Tank
IP67
Fuse Bush
IP67
Switch Cabinet Shell
IP44
Bus Bar
Bus Bar in Switch Cabinet
400mm²Cu
Earthing Bus Bar of Switch Cabinet
160mm²Cu
Thickness of Stainless Gas Shell
3.0mm

Transportation
 
During carriage & transportation, if necessary, fix the bottom bracket with nails. If transport by truck, should be fixed & carried by PE bottom bracket with plastic tape. 
 
Feature & Advantages
 
1 Fully sealing, insulating and protection meet the outdoor all-weather operating condition;
2 Anti-flood, dirty and dew & frost, the stainless steel housing added electros praying;
3 Ring main unit type cable branch box can achieve ring power-supply for several users, having the performances of safety, reliability and economical efficiency.
4 It can reserve interface and configure related elements (CT, PT, electric and operating mechanism) for distribution network automation, reserving FTU interface and position;
5 Cold shrinking accessories can be selected for silicone rubber drop-in, with simple and reliable installation.
 
Standards
 
DL/T 402-2007
DL/T 404-2007
DL/T 486-2000
DL/T 593-2006
DL/T 593-2006
DL/T 728-2000
GB 1984-2003
GB 1985-2005
GB 3804-2004
GB 3906-2006
GB 4208-2008
GB 11032-2000
GB 16926-2009
GB 15166.2
GB 50150-2006
GB/T 11022-1999
GB/T12706.4-2002
JB/T 10840-2008
IEC 60502-4:1997
 
Service
 
Shipping
 
1 Sea Way
2 Air Way
3 Express
 
Payment
 
1 PayPal
2 West Union
3 Wire Transfer
4 T/T
 
We’re always at your service, any question please feel free to contact us.