Specification:
Ambient temperature:32F to 131F(0C to 55C)
Relative humidity :10%-95%
Delivery temperature:-40F to 158F(-40C to 70C)
Power supply: AC185V-245V,50/60HZ
T/C type: J/K
Temperature Unit: C/F
Temperature control scope:45C to 550C
Temperature test precision:+3%
Repeat temperature measure precision :+0.1%
Temperature stable precision :+0.5%
T/C cooling compensation: Dynamic tracking
Noise restrain: common mode rejection ratio>100DB,
Sample frequency:10HZ(100mS)
One point load:15A
F1,F2,F3,F4:250V-15A(special fuse)
FUNCTION DESCRIPTION
With FUZZY PIDD control technology but without PID parameters, it can be automatically fit for any heating models and greatly improve the work capacity;
380V input protection , it can stop from controller damage by power input error
Heater output shorted protection :when heater and load are shorted ,controller will close output automatically, in case of hot runner temperature system damage.
Auto ambient temperature line compensation makes controlling more precice
T/C automatic cold compensation , in case of deviation due to ambient temperature change
T/C monitor error:
Controller can monitor sensor reversed and sensor open .When question is monitored ,it will be remended according to wrong type and mode.
Loop Break Detection
Warmer current monitor
Output Interruption Check
Leakage error monitoar (Ground Fault Detection Circuit);
Deviation Alarms;
Manual mode
Softstart function
Non-touch transfer;
Full wrong info display ,make you easier to find default reasons