Description & Application
SSOC (NCF) outdoor AC high voltage drop-out fuse series are installed on the distribution transformer or pole of power line for overload protection and load current switching on/off. It is composed of a main insulating & conducting structure and a fiber glass arcing tube. The stationary contacts are fixed at both ends of the insulating post and moving contacts at both ends of fuse tube, with an arcing chamber and elastic auxiliary contacts to interrupt load current and capacitor current.
Technical Parameter & Detail Show
Technical Parameter
Item | Data |
Rated Voltage | 12kV |
Rated Continuous Operating Current | 100A,200A |
Rated Frequency | 50Hz/60Hz |
Rated Fuse Base Current | 100A,200A |
Rated Short-circuit Breaking Current | 12.5kA,16kA(4times for 100A,1time for 200A) |
Rated Power Frequency Withstand Voltage | 60kV/50kV(dry/wet) |
Rated Lightning Impulse Withstand Voltage | 125kV/150kV(phase to earth/across the isolating distance) |
Creepage-distance | 372mm for Porcelain |
Mechanical Life |
2000times(continuous switch on-off) 500times(continuous switch on-off) |
Elevation | 2000m |
Ambient Temperature | -40~+70 |
Fuse tube - epoxy fiber glass with fiber lining coated with special ultraviolet resistant material, the disconnecting switch blade can be here selected.
Upper contact - silver to silver, high contact pressure squeezed by stainless steel spring.
Trunnion - high strength cast copper, silver plated, and pressed on the side surface of the hinge to ensure the fuse tube alignment while switching-on.
Each in a poly bag, then in a five corrugated carton with poly foam inside
1. The insulator fixing stem is fixed into insulator with white cement imported from America, together with tower structure it is very firm and quite suitable for outdoor application
2. Unique waterproof design and excellent contact structure, which are patented with our own.
3. The key mechanical parts are made of high quality brass, bronze and copper, supplying a longer life.
4. Conductive parts are all with silver plated pure copper or beryllium bronze, the thickness reaches as much as 20μ, reducing contact resistance and supplying a stronger conductive performance.
The design and test of SSOC (NCF) fuse are complied with the following standards:
ISO9001
IEC282.1 IEC787
ANSI C37.41-94 ANSI C37.42-94
GB 15166.3-2008 GB311.1-97
DL/T 640-97 DL/T 593-96