Product Main

Specifications

 
 
Digital Timer Cool/Heat Thermostat
 
 
Features:
  • Blue tape LCD display, simple operation
  • Temperature adjusted per 0.1°C
  • One timer can be set like 20:00~06:00
  • Uses a inbuilt real-time clock to control the light so simulating the day and night as in the real environment
  • Can be set with a separate day and night time temperature
  • Three kinds of temperature alarms, mute function available
  • Can be used in both wet and dry environments
  • Backlight auto shut down if without operation for 10 minutes
  • Small in size making it stylish and discrete
Parameters:
  • Controlling range: 0.0~50.0°C
  • Measuring range: 0.0~50.0°C
  • Resolution: 0.1°C; Accuracy: ±1.0°C
  • Over heat alarm: 0.0-5.0°C(can be modified)
  • Time unit: hour (24:00 format)
  • Relay Capacity: 10A/220V
  • Input voltage: 220VAC±15%,50/60HZ(Optional:110VAC)
  • Product consumption: ≤3W
  • Control load: ≤1200W/220VAC
  • Socket size: 235x70x40mm
  • Net weight: approx. 620g; Gross weight:approx. 720g
  • Two independent sockets –First socket (nearest power cable) is for heating output; Second socket is for the timer output (for lighting for example). (Optional:AU, EU, USA, UK,OTHER TYPE)
Package Included:
 
  • 1 x thermostat(power strip included)
  • 1 x user manual
 
Symbol:
 Icon flashing: Heating output;                                    Icon flashing: The timer is on;
 Icon flashing: Alarm status over temperature          Icon: Clock
 Icon visible: Daytime;                                                 Icon visible: Nighttime
Button:
: Save; : Up; : Down; : Set
 
Menu instructions:
 
Menu item
Set
Default value
Remark
HEAT/COOL(MODE)
HEAT/COOL
HEAT
COOL mode delay 1 min.
Temp. Setting
0.0~50.0°C
22.0°C
Adjusted per0.1°C
Alarm variation temperature
0.0~5.0°C
5.0°C
Adjusted per0.1°C
Temperature Differential(DL)
0.0~10.0°C
3.0°C
Adjusted per0.1°C
1st Timing control (L1):
ON: FROM, OFF: TO
00:00~23:59
00:00~06:00
Disabled if FROM and TO are same
CLOCK
00:00~23:59
Real-time
24 Hour Clock

General Setting Note: 
 
  • Parameters of temperature and timers can be viewed by pressing  UP or DOWN key in normal status.
  • If you do not complete a setting and the unit is left and settings are not saved, the product returns to default settings automatically if no key is operated within 15 seconds.
Upper and lower temperature limits setting:
You can set a limit to the temperature range that your thermostat operates at. The default is between 0°C -50°C but you can reduce this range. To do this, in normal working status:
  • Highest temperature limit setting: Press  UP  button for 5 seconds to display default upper temperature limit settings and then press UP or DOWN button to modify the set value.
  • Lowest temperature limit setting: Press  DOWN button for 5 seconds to display default lower temperature limit settings and then press  UP or DOWN button to modify the set value.
Temperature alarming:
There are three temperature alarms. The firstis for when the temperature exceeds the set ‘TEMP ALARM’ selected earlier. The unit will beep and the alarm icon flashes in the below situations:
  1. The measured temperature > the set temperature + set over temperature
  2. The measured temperature < the set temperature –set over temperature
The second alarm occurs when the Lowest or Highest set temperature is exceeded. In default mode, the alarm will sound and the alarm icon flashes in the below situations:
  1. The measured temperature <0.0°C(the Lowest set temperature).’LLL’ will also flash.
  2. The measured temperature >50.0°C(the Highest set temperature). ‘HHH’ will also flash.
The last alarm is for if the probe has an open or short circuit. The unit will display an error message for the probe fault ‘ERR’ and the alarm will sound.
Mute alarming manually:
  1. When an over temperature alarm sounds, you can press any key to mute this. However, a probe fault alarm sound cannot be muted.
  2. You can set whether you have the alarm on or off. Press  and  at the same time for 3 seconds. The option becomes available to choose whether to turn the alarm sound on or off. AL: Alarm sound on, NO: No alarm sounds. Choose the option you require by using the  or  button and Press <button to finish and exit.
 
Friedly Reminder:
  • We can provide customized service for all of our products with reasonable price.
 
Applications:
1. Refrigeration industry(freezers, refrigerators, , Cold stores, cold chain, iceboxes, cooling towers, water coolers, oil coolers, cold water chillers, water chilling units etc.)
2. HVAC industry (Heating Ventilation Air Conditioning)
3. Pet industrial: Aquariums, fish tanks, terrariums, seafood machines, Vivariums, Paludariums, Incubators etc.
4. Medical thermostatic equipment (for blood, drugs, Pharmaceutical etc.)
5. Food processing (Brewing, Abattoirs etc.), Food Wholesale, Food Retail (Hypermarkets, Supermarkets, Convenience Stores, Food Shops, Charcuteries, Delicatessens etc.)
6. Solar water-heating system central controller
7. Sauna room, foot bath, foot sauna, foot massager etc.
8. Wine production, wine cabinet, display cabinet etc.
9. Catering (Hotels, Restaurants, etc.)
10. Agriculture
11. Automobile
12. Photography
13. Process control
14. Laboratory, Chemical
15. Greenhouses, cultivating-houses
16. Ice-skating rinks
17. Energy management
18. Other industries need temperature measuring and controlling