Differential Pressure Flow Switch BWFS10 Overview
BWFS 10 series differential pressure flow switch with single fixed set point was
designed for OEM customers. It was designed to be compact, cost-effective,
differential pressure switch for application such as proof-of-flow, filter
monitoring, etc. The pre-setting value can not be changed, which can ensure
the flow setting value can not be changed. Our company considerate
the practical situation, can transfer the setting differential pressure value to
the flow protection value of the heat exchanger. The value can set by our
professional according to customer’s requirement and print on the label.
designed for OEM customers. It was designed to be compact, cost-effective,
differential pressure switch for application such as proof-of-flow, filter
monitoring, etc. The pre-setting value can not be changed, which can ensure
the flow setting value can not be changed. Our company considerate
the practical situation, can transfer the setting differential pressure value to
the flow protection value of the heat exchanger. The value can set by our
professional according to customer’s requirement and print on the label.
Differential Pressure Flow Switch BWFS10 Features
△ Storage temperature: -29℃~82℃
△ Ambient temperature: -20℃~71℃
△ Media temperature range: -20℃-93℃
△ Pressure connection: 1/4" SAE(7/16" –20UNF)G, 1/4"NPT for optional)
△ Max. static pressure: 10bar
△ Max. pressure difference: 5bar
△ Set point repeatability tolerance: ±1%
△ Output: one SPDT dry contact output, one or two for optional factory set
one N/O.
△ Switch: 10A(max), 125/250VAC
△ Electrical connection: DIN 43650 /direct connect(105℃ resistance
burning 2×0.75 or 3×0.75mm for optional)
△ Ambient temperature: -20℃~71℃
△ Media temperature range: -20℃-93℃
△ Pressure connection: 1/4" SAE(7/16" –20UNF)G, 1/4"NPT for optional)
△ Max. static pressure: 10bar
△ Max. pressure difference: 5bar
△ Set point repeatability tolerance: ±1%
△ Output: one SPDT dry contact output, one or two for optional factory set
one N/O.
△ Switch: 10A(max), 125/250VAC
△ Electrical connection: DIN 43650 /direct connect(105℃ resistance
burning 2×0.75 or 3×0.75mm for optional)
Differential Pressure Flow Switch BWFS10 Application
Typical applications include flow controlling and monitoring for pump and filter in air-cooled water chiller, water-cooled
chiller those use plate-type heat exchanger, double-pipe heat exchanger and shell-and-tube heat exchanger.
chiller those use plate-type heat exchanger, double-pipe heat exchanger and shell-and-tube heat exchanger.