Product Main

Quick Details

Electricity Type: AC
Main Circuit Rating Voltage: 1000V
Maximum rated current for motor control : 115A -630A
Phase: 3
Number of Pole: 3
Certificate: CE,CCC

Specifications

Specifications  
CJX2-F(LC1-F) AC Contactor /Contactor Electrical /Electrical Contactor
1)CE,CB,ISO9001,14001
CJX2-F(LC1-F) AC Contactor /Contactor Electrical /Electrical Contactor 
 
General:
   CJX2-F series AC contactor is applicable in the circuit rated voltage up to 1000V AC. 50/60Hz, rated current up to 781A, for long distance breaking curcuit and frequency starting or controlling the motor. It also can be used for the control of distributing ciurcuits of rated current from 200A to 1600A(AC-1)/115A to 780A(AC-3). The products cmply with IEC 60947-4.
 
 
Type
CJX2-F115
CJX2-F150
CJX2-F185
CJX2-F225
CJX2-F265
CJX2-F330
CJX2-F400
CJX2-F500
CJX2-F630
Main circuit characteristic
Poles
3P.4P
Rated operation voltage (Ue
V
380,660,1000
Rated insulation voltage (Ui
V
1000
Rated heating current (Ith)
A
200
200
275
275
315
380
450
630
800
Rated operation current (Ie)
AC-3 380V
A
115
150
185
225
265
330
400
500
630
AC-3 660V
A
86
108
118
137
170
235
303
353
462
AC-3 1000V
A
46
51
71
90
112
115
200
232
331
AC-4 380V
A
52
60
79
85
105
117
138
147
188
AC-4 660V
A
49
61
69
82
98
118
135
145
170
Max.power of 3 phase motor controlled
AC-3 220V
Kw
30
40
55
63
75
100
110
147
200
AC-3 380V
Kw
55
75
90
110
132
160
200
250
335
AC-3 660
Kw
80
100
110
129
160
220
280
335
450
Electrical life
AC-3
10000t
60
50
30
20
AC-4
10000t
1.5
1.5
0.8
0.5
Machinery life
10000t
600
600
500
500
Operation Frequency
AC-3
t/h
600
600
300
300
AC-4
t/h
150
150
150
150
Matching fuse type
RT16-160
RT16-200
RT16-250
RT16-315
RT16-400
RT16-400
RT16-500
RT16-630
RT16-800
Matching thermal relay type
LR9-F53
LR9-F73
Wiring capacity
mm²
50
50
95
95
150
185
30X5(2)
40X5(2)
50X5(2)
Coil
Control power voltage (Us)
AC
V
48,110,220,380,440,660,
Allowed control circuit voltage
Close
V
85%~110%Us
Open
V
20%~75%Us(AC)
Coil power
Close
VA
550
800
1200
1200
1250
1650
Keeping
VA
45
55
13
20
24
22
Loss power
W
12~16
18~24
12
14
18
20
Auxiliary contact
Rated heating current (Ith)
A
10
Rated operation voltage (Ue)
AC
V
380
DC
V
220
Rated control capacity
AC-15
VA
360
DC-13
W
33
 
 
 
Ambient temperature    
-5~+40
Altitude
≤2000m
Relative humidity   
The maximum temperature of 40 degrees, the air relative humidity not exceed 50%, at a
lower temperature can allow for a higher relative humidity, if humidity changes as a result
of occasional gel generated,should eliminate it.
Pollution level
3    
Installation category
III
Installation position
The installation degree of the tilt and vertical plane should not exceed ±22.5°,
should be installed in place with no significant impact shaking and vibration 
Install