Product Main

Quick Details

Nominal Area: 10mm2--185mm2
Type: Welding Cable
Standard: IEC60245,as Requirements
Insulation Thickness: 1.8mm--3.2mm
Min O.D: 7.5mm--22.0mm
Max O.D: 9.7mm--29.0mm
Colour: As Request
Rating Voltage: 100/1000V
Price: Best Price
Service: Excellent Service

Specifications

Introduction 
Welding cable is used to power the secondary circuit of electric arc-welding generators, the circuit that controls the electrode that emits the charge used to weld. This cable is made from flexible copper wire surrounded by a protective covering that is resistant to flame, heat, oil and abrasions, among other things. While welding cable is not meant to be part of any other system, it has a history of being used for public lighting arrangements.
 
A pair of electric cables supplying power from a welding machine to the work being done; one lead connects the machine with the electrode holder, the other lead connects the machine to the work
 
Standard
245 IEC 81, 245 IEC 82, BS638, IS 473
 
Feature 
1. high flexibility properties
2. Outstanding toughness and durability.
3. High resistance to cuts, tears and abrasion.
4. Resistance to oil, solvents and chemicals.
5. The permissible continuous operating temperature is 65°C
 
Application
These cables are used for connecting the electrodes to the welding equipment. These cables are used in the automobile industry in shipbuilding, in transport and conveyor system, tool making machinery, welding robots etc. These cables are suitable for welding equipment industry, in automated welding equipment, in tooling constructions, automobile and ship building as well as for hand-held electrodes in workshops and at building sites. These flexible and robust current-carrying cables are suitable for use at high mechanical loads in dry, moist and wet rooms as well for outdoor applications.
 
Model, Name&Application
Model
Name
Main applications
Working temperature
of core ≤0C
60245-81(YH)
Natural Rubber Sheath for Welding Cable
Always used indoor
65
60245-82(YHF)
Neoprene Rubber Sheath Welding Cable
Always used outdoor
65
 
Specification
Conductor Nominal Section (mm2)
Conductive Core
Thickness of Section Sheath (mm)
Average Outer Diameter (mm2)
200C Conductor Resistance≤(Ω/km)
Number/Diameter of Core(mm)
Min
Max
10
322/0.20
1.8
7.5
9.7
1.91
16
513/0.20
2.0
9.2
11.5
1.16
25
798/0.20
2.0
10.5
13.0
0.758
35
1121/0.20
2.0
11.5
14.5
0.536
50
1596/0.20
2.2
13.5
17.0
0.379
70
2214/0.20
2.4
15.0
19.5
0.268
95
2997/0.20
2.6
17.0
22.0
0.198
120
1702/0.30
2.8
19.0
24.0
0.161
150
2135/0.30
3.0
21.0
27.0
0.129
185
1443/0.40
3.2
22.0
29.0
0.106