Product Main

Specifications

 
                               Iron phosphate coating agent IC-3001
 
1. Process flow
1.1 Degreasing(alkaline) → Water Rinsing → Rust Cleaning → Phosphating → Water Rinsing → Drying
1.2 Degreasing(acid) → Rust Cleaning → Water Rinsing → Phosphating → Water Rinsing → Drying
1.3 Grease and Rust Cleaning → Water Rinsing → Phosphating → Water Rinsing → Drying
2. Solution preparation (1 ton)
  The weight ratio of phosphate coating agent and water is 1 : 9, that means there are phosphating solution of 100 kg and water of 900 kg in working solution of 1 ton. The pH of working fluid is 3 to 4.
3. Performance indicators
Code number
Items
Indicators
1
Processing Mode
Dipping or Spraying
2
the Weight of Phosphate Coating
1 to 2 vm
3
the Scope of total acid (TA)
25 to 50
4
the Scope of free acid (FA)
1 to 3
5
Temperature
Dipping: Room Temperature
Spraying: 20 to 45 degrees
6
Time
Dipping: 5 to 15 min
Spraying: 2 to 3 min
7
Coating Adhesion (level)
0
8
Wearing Quality 3 % NaCl (H)
> 1
9
The handling capacity of concentrated phosphating liquid (m*m/kg )
> 80
4. Detection method
4.1 Total acidity (points)
  Taking 10 ml working fluid to the conical flask, and adding phenolphthalein indicator of 3 to 5 drops. Titrating above-mentioned solution by 0.1 M sodium hydroxide standard solution from colorless to red. The quantity (ml) of 0.1 M sodium hydroxide standard solution is called the points of total acidity.
4.2 Free acidity (points)
  Taking 10 ml working fluid to the conical flask, and adding bromophenol blue indicator of 2 to 4 drops. Titrating above-mentioned solution by 0.1 M sodium hydroxide standard solution from yellow to blue. The quantity (ml) of 0.1 M sodium hydroxide standard solution is called the points of free acidity.
5. Additions and adjustments (1 ton)
  After using a period of time, phosphating working solution will lose activity. When total acidity is normal, but free acidity is too low, phosphate coating agent can be added.
Theoretical calculations: Adding phosphate coating agent of 5 kg can improve one point of the points of free acidity, and 4.2 kg can improve a total acid points.