Features:
5.7" LCD display can display the US and TOCO Data and monitoring curve;
FHR collection signal for quality indication, alarm indication for abnormal FHR, Fetal movement indication;
Coding keyboard adjusts all parameter setting of unit, memory and replay the data in 24 hours(for option);
5.7" LCD display can display the US and TOCO Data and monitoring curve;
FHR collection signal for quality indication, alarm indication for abnormal FHR, Fetal movement indication;
Coding keyboard adjusts all parameter setting of unit, memory and replay the data in 24 hours(for option);
Record FHR, UC, FM mark, necessary character interpretation and monitoring time synchronously with 832 thermal linear array printer;
Curve printing speed, line of thin or thick, signal collection rate can be adjust for the requirements of user, the printing speed can be setup to 1,2,3cm/min;
Adjust the upper and lower alarming limit, real time, date and other parameter, the set-up data can be saved automatically after powered off;
The monitoring data can be conveyed to the exterior computer by RS-232.
Specifications:
FHR
Probe: 9 crystals, wide wave beam
Working mode: Pulsed Doppler
Ultrasonic frequency: 1.0MHz±10%
Ultrasonic average intensity:≤10mW/cm2
Signal processing: signal processing units for special digital signal
FHR range: 50--240bpm
Alarm range:Up: 55-240bpm Low: 50-235bpm
Printing resolution: 27bpm/cm
The highest frequency output: ≤5W
Overall sensitivity:≥90dB
TOCO
Display range: 0--100units ((nonlinear error: ≤±10%)
Printing resolution: 40units/cm
Display: display monitoring status for US and TOCO curve, fetal movement mark, doctor mark, time, volume, and freeze the current monitoring status
Battery: NI-MH 16.8V/1800mA rechargeable batteries group
Time of continue working in static condition: ≥2 hours
Power supply: AV 100--240V 50Hz/60Hz DC 24V±1V
Consume power: ≤50W
Working Temperature: 10--40°C Humidity: ≤80%
Atmospheric pressure: 86--106kPa
Packaging collocation:
Single Unit Suitcase Package Dimension: 55cm x 26cm x 36cm Gross weight: 10.5kg
Single Unit Paper carton Package Dimensiont: 55cm x 26cm x 36cm Gross weight: 8kg
Display: display monitoring status for US and TOCO curve, fetal movement mark, doctor mark, time, volume, and freeze the current monitoring status
Battery: NI-MH 16.8V/1800mA rechargeable batteries group
Time of continue working in static condition: ≥2 hours
Power supply: AV 100--240V 50Hz/60Hz DC 24V±1V
Consume power: ≤50W
Working Temperature: 10--40°C Humidity: ≤80%
Atmospheric pressure: 86--106kPa
Packaging collocation:
Single Unit Suitcase Package Dimension: 55cm x 26cm x 36cm Gross weight: 10.5kg
Single Unit Paper carton Package Dimensiont: 55cm x 26cm x 36cm Gross weight: 8kg
Normal collocation: 1 x 1.0MHz probe, TOCO probe, remote Marker, switch power, cable, 250ml gel, operation manual, warranty card, approval certification, 2 pcs printing paper.