Leading electromagnetic flow meter supplier in China
For more details, pls feel free to contact me!!!
Technical Parameters of the electromagnetic flowmeter
|
|
SE11
|
SE12
|
SE13
|
SE14
|
|
Measuring flow
|
electrically conducting liquids
|
|||
|
Precision
|
±0.5%
|
±0.25%
|
±0.5%
|
±1.5%
|
|
Repetition
|
±0.25%
|
±0.125%
|
±0.25%
|
±0.75%
|
|
Medium
Temperature
|
-25℃~130℃
|
-25℃~130℃
|
-25℃~200℃
|
-25℃~130℃
|
|
Conductivity
|
≥5µs/cm (Please consulate with us if it is less than 5μS/cm)
|
|||
|
Diameter(mm)
|
3~2200
|
3~2200
|
3~125
|
300~3000
|
|
Pressure Level
|
0.6Mpa/1.0Mpa/ 1.6Mpa/2.5Mpa/4.0Mpa
|
|||
|
Range of
Velocity
|
0.5~10m/s
|
|||
|
Flow Direction
|
Positive/negative
|
|||
|
Electrode
|
316L, Hastelloy, Ti, Ta, Pt-Ir
|
|||
|
Lining Materials
|
Rubber/PTFE/PFA
|
PFA
|
PTFE
|
|
|
Form of electrode
|
Standard
|
|||
|
Quantity
of electrode
|
Two pairs(Measure, grounding)
|
A pair(measure)
|
||
|
Tube
|
304
|
304
|
||
|
Flange
|
Carbon steel/304
|
304
|
304
|
|
|
Installing form
|
clip/flange
|
clamp/thread
|
flange/plunge
|
|
|
Protection Level
|
IP65/IP68(Divided type)
|
|||
|
Power
|
220VAC±20% 60HZ /24VDC
|
|||
|
Signal output
|
4-20mA
|
|||
|
Communicate
|
HART/Modbus/Profibus
|
|||
|
Electric
Connections
|
2×M20*1.5
|
|||
|
explosion proof
|
non-explosion-proof/Exe dib IIB T4 explosion proof
|
|||
|
type
|
Integrated type/ Divided type
|
|||
|
Ambient
Temperature
|
-25~60℃
|
|||
For more details, pls feel free to contact me!!!